Laserfiche WebLink
QUALITY ASSURANCE AND QUALITY CONTROL PLAN <br />The Remedial Investigation (RI) Quality Assurance/Quality Control (QA/QC) program is <br />intended to facilitate the acquisition of accurate and reliable data. Environmental data gathered <br />during the RI will be collected and analyzed following procedures prescribed in the Quality <br />Control Program. A Quality Assurance Program has been established to assure that the Quality <br />Control Program is effective. Both programs are necessary to provide accurate data and <br />documentation for investigations and laboratory analyses. The following field and laboratory <br />procedures will be implemented to ensure that QA/QC objectives are met. <br />1.0 RECORDING OF FIELD DATA <br />All information pertinent to the field investigation will be kept in a field log book. Information <br />to be documented includes at least the following: <br />- Sample numbers <br />- Locations of sample collection <br />- Soil boring or well numbers, as applicable <br />- Depths at which samples were obtained <br />- Names of collectors <br />- Dates and times of collection <br />- Purpose of sample <br />- Sample distribution (e.g. laboratory, archive, etc.) <br />- Field observations <br />- Field measurements (e.g. PID readings, pH, conductivity, water levels). <br />- Other data records (e.g. development log, soil sampling report, well log, etc.) <br />2.0 SAMPLE CONTAINERS <br />Groundwater samples will be placed in containers supplied by the analytical laboratory. Table <br />1 summarizes the required sample containers. <br />