My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
INSTALL 2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2019 11:38:25 AM
Creation date
5/8/2019 11:47:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2002
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
202
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IN <br />L <br />`1 <br />A <br />GENERAL NOTES UNLESS OTHERWISE SPECIFIED: <br />PORTABLE BUILDING SYSTEM --- FACTORY ASSEMBLED PREFAB— <br />BUILDINGS, COMPLETELY ASSEMBLED AND READY FOR RAPID <br />INSTALLATION AT JOBSITE BY OTHERS USING ONLY A FORK-- <br />LIFT FOR EASY REMOVAL FROM TRUCK. <br />CONSTRUCTION — 14 GAUGE GALVANIZED STEEL WALL PANELS. <br />FRAME CONSTRUCTED FROM 2" x 2" STEEL TUBING. 14 GAUGE <br />GALVANIZED STEEL ROOF SYSTEM. <br />WELDING — ALL WELDS SHALL BE INERT GAS SHIELDED ARC <br />WELDS. ALL WELDED JOINTS TO BE GROUND SMOOTH. WELDS <br />AND MATERIAL SHALL MEET OR EXCEED THE FOLLOWING <br />AMERICAN WELDING SOCIETY SPECIFICATIONS: <br />AWS D1.3 SPECIFICATION FOR WELDING SHEET STEEL IN <br />STRUCTURES, <br />AWS A5.118 STEEL CARBON. FILLER MATERIAL FOR GAS SHIELDED <br />ARC WELDING. <br />ALL WELDERS ARE CERTIFIED TO MIL STD1595A. <br />ELECTRICAL SYSTEM -- UNIT SHALL BE DELIVERED COMPLETELY <br />WIRED AND READY FOR POWER INTERCONNECTION BY OTHERS. <br />ALL WIRING/CONDUIT SHALL BE CONCEALED IN WALLS, ALL <br />ELECTRICAL COMPONENTS WILL BE UL LISTED AND INSTALLED <br />IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE. <br />7 <br />UNIT <br />CB# 3 <br />LIGHT <br />CE <br />OUTLETS <br />CB# 2 <br />ONE (1) 20" DEEP STAINLESS <br />STEEL COUNTER 36" A.F.F. WITH 2" DIA. <br />ELECTRICAL ACCESS PORT (TYP. 2) AND <br />ONE (1) 20" DEEP STAINLESS <br />STEEL COUNTER BENEATH AT 18" A.F.F. <br />�! r <br />TWO (2) 8" DEEP REMOVABLE <br />STAINLESS STEEL EXTERIOR SHELF <br />I <br />4 <br />1 1 ! <br />I! <br />� I 1 <br />i <br />(1) TRANSACTION DRAWER <br />I <br />BW82020 WIDE BODY <br />DEPOSITORY CHEST <br />TO BE BY OTHERS <br />I <br />! <br />I <br />18 OVERHANG IN FRONT. <br />"'L <br />2 ELECTRICAL PLAN <br />1 1 <br />DOOR(S) SLIDING DOOR FRAME FABRICATED FROM STRUCTURAL <br />STEEL TUBING AND DESIGNED FOR HEAVY DUTY INDUSTRIAL USE. <br />DOOR SHALL HAVE ALUMINUM TOP SUSPENSION TRACK WITH BALL <br />BEARING CARR[FRS, HEAVY DUTY SECURITY DOOR JAMB. HEAVY <br />DUTY LOCK/LATCH. DOOR(S) FULLY WEATHER STRIPPED, SWING— <br />OPEN DOORS SHALL HAVE HEAVY DUTY HINGES, <br />GLAZING SYSTEM — ALL STEEL WINDOW FRAMES WITH STEEL <br />INTERIOR GLAZING KEEPERS. <br />SHELVING — HEAVY DUTY STAINLESS STEEL COUNTER. <br />WEATHER RESISTANCE m- ALL METAL JOINTS ARE SEALED AGAINST <br />WEATHER AND WATER INTRUSION, WEATHER STRIPPING IS PROVIDED <br />AT ALL WINDOWS AND DOORS. <br />FINISH — UNIT PRIMED, SEALED AND PAINTED IN ACCORDANCE WITH <br />THE STANDARDS ESTABLISHED BY THE STEEL STRUCTURES PAINTING <br />COUNCIL FINISH TO HAVE GOOD FADE, IMPACT AND CHEMICAL <br />RESISTANCE, COLOR TO BE SELECTED BY CUSTOMER. <br />1.50 <br />I <br />4 I 3 <br />ALL CONDUIT TO TERMINATE <br />-36.00IN REAR ELEVATION AT 24" TWELVE (12) 2x2x3x1/4" STEEL <br />- - roll ABOVE FINISHED FLOOR ANGLES FULLY WELDED TO FLOOR <br />-,,Z/ <br />BASE FOR USE AS ANCHOR POINTS, <br />° WITH 3/4" DIA. HOLES. <br />°I B <br />1 <br />060.00 <br />I <br />f <br />! <br />! <br />3/4" PLYWOOD FASTENED ON <br />------ INTERIOR SHEET METAL & PAINTED <br />I TO MATCH BUILDING. <br />I <br />! <br />aP <br />j <br />1.50 <br />-24.00— <br />FLOOR <br />24.00 <br />FLOOR PLAN <br />1 1 <br />r � <br />2" OVERHANG ON SIDES <br />AND REAR. <br />060.00 <br />I f 4 I1 ! <br />€E ! <br />i! <br />!! <br />I! <br />6 <br />II <br />5 <br />7 <br />ROOF DRA#N DOWN <br />REAR CORNER POST <br />(TYP. 1) <br />ACOUSTICAL <br />CEILING PAN <br />IN T—BAR SYS <br />3 CEILING PLAN <br />1 ul <br />NOTES <br />AC UNIT — 120 VOLT, 1—PHASE, 13,500 BTU <br />COOLING AND ROOF MOUNTED WITH INTEGRAL <br />THERMOSTAT/FAN CONTROLS. <br />24"x48" FIXTURE WITH TWO (2) 40 WATT FLUORESCENT <br />BULBS. RECESSED MOUNTED IN T—BAR GRID SYSTEM <br />ACOUSTICAL DROP CEILING. <br />PROJECT <br />STOCKTON, CA <br />CONTRACT No. INTERTEX JOB No, <br />01-' 383 <br />FOR <br />FLEMING FUELS <br />0 <br />ELECTRICAL LEGEND <br />15 AMP, 115V QUADPLEX OUTLET. <br />15 AMP, 115V DUPLEX OUTLET. <br />--�— 15 AMP, 115V SINGLE POLE TOGGLE SWITCH. <br />4X4 JUNCTION BOX. <br />� �N7[Epuvx <br />rr�� p mom o B o oth@v OP116a <br />ii•Iwllrlllt•� APPROVAL DRAWINGS <br />❑ APPROVED AS DRAWN <br />❑ APPROVED Yffffl REVISIONS <br />❑ NOT APPROVED REST <br />SKMTURE• DATE: <br />PUNT NAME: <br />APPROV�A ❑RAWIN43 ARE REQUIRED BEFORE <br />YOLiR ORDER IS � TO PR�UCTION. <br />A <br />ADDT'L <br />4x4 COLUMNS PER JRMA <br />I MS107/16/011 <br />1 <br />REV. <br />DESCRIPTION <br />I DRWN BYJ <br />DATEAPPVD <br />BY <br />DATE <br />m <br />25100 RYE CANYON <br />NOTE , REMN uNIESS OTHLRWISE <br />NOTED, R THE CSECRET <br />M�(' � <br />[I I E <br />BUSINESS CENTER PARK, BLpG, 3 <br />AND <br />PRQPERTY AND iRAOE SOCKET OF <br />OF <br />11 IJ ll <br />VALENCIA , CALIFORNIA 91355 <br />INTERTEx, INCORPORATED <br />k7 SHALL NOT BE DIVS10N. <br />PARKING SYSTEMS DILOSED. <br />a <br />C7 & BD oo h� Mc. <br />[] 0FAX <br />PHONE — 661-295-0339 <br />- 661-295-3235 <br />REPRODUCED OR USED FORW <br />MANUFACTURE, DESIGN OR <br />- <br />W.INTERTEX—GC,COM <br />CONSMUCTION WITHOUT THE <br />TER EX BARIRERS & <br />GENERAL PLANS, ELEVATIONS, SECTIONS & DETAILS <br />�a°T" INCORPORATED. <br />THE RECIPIENT 8Y ACCEPTINGCEHNG THIS <br />MODEL N0, CUS814—RR <br />DRAWING, ASSUMES CUSTODY <br />TBOVE <br />AGREES NOT To <br />ERMS RE UNDER TO ALLOW <br />UNLESS OTHERWISE NOTED <br />DRAWINC NO. <br />REV <br />USE <br />USE OF BY UNAUT"gRIXED <br />UNAUTHORIZED <br />PFIRSDNs. <br />DIMENSIONS ARE IN INCHES <br />i O 9- 1 <br />1 "/-'��' <br />1409-1 <br />A <br />DRN/N BY <br />DATE <br />M. SALAMANCA <br />07/12/01 <br />02001 <br />ALL RIGHTS RESERIED <br />APPA) BY <br />DATE <br />SCALE: <br />1 /2" - 1'_0" <br />SHEET <br />1 SHEET 1 OF 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.