My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MUNFORD
>
3730
>
2800 - Aboveground Petroleum Storage Program
>
PR0531150
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2019 1:50:57 AM
Creation date
5/10/2019 8:51:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0531150
PE
2832
FACILITY_ID
FA0014437
FACILITY_NAME
Intermodal 1
STREET_NUMBER
3730
Direction
E
STREET_NAME
MUNFORD
STREET_TYPE
AVE
City
STOCKTON
Zip
95215
APN
17956010
CURRENT_STATUS
01
SITE_LOCATION
3730 E MUNFORD AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> COUNTY- <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> NORCAL TRANSPORT REFRIGERATION 3730 E MUNFORD AVE, STOCKTON May 09, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 718 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable <br /> containers. <br /> Two 55 gallon drums of motor oil were observed with insufficient secondary containment. One blue metal and one <br /> red metal drum of motor oil were observed on the north wall of the shop without secondary containment. Portable oil <br /> storage containers must be positioned or located to prevent a discharge and shall be furnished with a secondary <br /> means of containment sufficient to contain the capacity of the largest single container with sufficient freeboard to <br /> contain precipitation. Immediately provide sufficient secondary containment for this and all other portable containers <br /> at this facility, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> On page 8 of the SPCC plan the plan states that there will be oil drums on site. On page 9 of the SPCC Plan on the <br /> facility map one oil drum is indicated. On page 31 of the SPCC plan it says that the facility"has no mobile or <br /> portable containers within their oil product system". Two 55 gallon drums of motor oil were observed during the <br /> inspection. For mobile or portable containers,either provide the type of oil and storage capacity for each container <br /> or provide an estimate of the potential number of mobile or portable containers,the types of oil, and anticipated <br /> storage capacities. Ensure that the SPCC plan accurately reflects portable and mobile containers. Submit a copy of <br /> the amended plan to the EHD for review. <br /> This is a Class II violation. <br /> 720 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping. <br /> -The facility map on page 9 of the SPCC plan indicates buried piping from the 12,000 gallon diesel tank to the fuel <br /> island. Page 30 of the SPCC plan states that"there is no underground piping on site for the oil products". <br /> Buried piping that is installed or replaced after August 16, 2002,shall be provided with a protective wrapping and <br /> coating and cathodically protected. Immediately provide all buried piping installed on or after August 16, 2002, a <br /> protective wrapping and coating and cathodic protection and ensure that the SPCC plan accurately discusses the <br /> buried piping in the SPCC plan. Submit a copy of the amended SPCC plan to the EHD. <br /> This is a Class II violation. <br /> 4010 The Substantial Harm Criteria certification form was not included with the SPCC plan. If the facility does not meet <br /> the substantial harm criteria listed in Attachment C-1 to this appendix,the owner or operator shall complete and <br /> maintain at the facility the certification form contained in Attachment C-II to this appendix. In the event an alternative <br /> formula that is comparable to the one in this appendix is used to evaluate the substantial harm criteria,the owner or <br /> operator shall attach documentation to the certification form that demonstrates the reliability and analytical <br /> soundness of the comparable formula and shall notify the Regional Administrator in writing that an alternative formula <br /> was used. Ensure that the SPCC plan contains the Substantial Harm Criteria certification form. Submit a copy to <br /> the EHD. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> FA0014437 PR0531150 SCO02 05/09/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 5 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.