MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
COMPLIANCE INFO 1997 - 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/10/2019 4:09:41 PM
Creation date
5/10/2019 2:31:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997 - 2005
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
318
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Doc-17-2003 09:11 am From-ARCO PRODUCTS +714-670-3095 T-739 P.001/004 F-282 <br /> MO RING SYSTEM C;r:tiTIN t to v <br /> r Use By Ah Jurisdictions YYrthin ihe.S7ate u(Cah),.. la <br /> Authority Cfled- Chapter 6.7,Heakh and Safety Code; Chapter 16,Dh-ision 3, Title 23, Calffornia Code of Regidarions <br /> This form must=used to document testing and servicing of monitoring equipment.Ascpa_rate certification or report must be arenared <br /> for each moritoriie system control Ranel by the technician who performs the work, A copy of this form must be provided to the / `_J <br /> system owner/operator. The owner/operator must submit a copy of this fora:to the local agency regulating UST systems within Inv�DD <br /> days of test date. <br /> A. General Information UkL 1 ' 2003 <br /> Facility Name: ARCO PRODOCTS COMPANY Service Station No.: 6313 <br /> 41 I HEALTH <br /> Site Address: 1100 S.Main Street City, Manteca Zip: siffiWIT/SERVICES <br /> Facility Contact Perion: �1 G},N ,� e-• _ Contact Phone No.; ui S13 S <br /> Make/Model of Monitoring System: c 'n aG w 'TSS . - Date of TestingrService: <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropKiate boxes to indicate spetifle equipment inspected/Seri iced: <br /> Tank ID: 2 i Tank ID- <br /> �)In-Tank Gauging Probe: Model: 514 7_Jp3•Ia•? 1 Oln-Tan)(gauging Probe: Model: <br /> Annular Space or Vaulc Sensor; :Model: 7g y 31 t.-4,0 cLi ©.kM=hr Space or Vault Sensor Model: Q'1 14 <br /> l;Piping Sump/Trench Scusor(s): Model: w 3pPiping Sump/Tr=ch Sensor(s): Model• 71 ,(.V,- Ya'r <br /> ❑Fill Sump Sensor(e): Model: []Fill Swnp Sensor(s): Model: <br /> 53Mechanical Line Leak Detector. Model: (_19 2-sn F,�iMechaiiical Line Leak Detector. Model: ^Z7} <br /> ❑Electronic Line Leak Detector Model• ❑Electronic Line Leak Detector Model: <br /> ❑Tarek Ovcrftll/High-level Sensor. Model: []Tank CGverfcll/High-level Sensor. Model: <br /> []Other,Specify equip,t e and:nodes ir.Section l✓on:p•ne 2 ❑Other, specify equip.rope and model;n Section E or.P_aee 2 <br /> Tank IIs: Qi r Tank ID: <br /> On-Tank Gauging Probe: ?Model: rte "14 I i,4`S ❑In-Tank.Gauging Probe: Model: <br /> EAnnular Space or Vault Sensor: Model: 5j�J, c )'i. [:Annular Space or'Vault Sensor Model: <br /> ®Piping S pi Trench Sensor(s): Model: ttLt 7:4 • []Piping Sump/Trench Sensor(s): Model: <br /> GFill Sump Sensor(s): Model: q ❑Fill Su'Op Sensor(a): Modes: <br /> ZMechanical Lire Leak Detector. Model: 7? m:.O ❑Mechanical sine Leak Detector. Model: <br /> CElectronic Line Leak Detector Model: ❑Electronic Line Leak Detector Madel: <br /> ❑Tank Overfill/High-level Sensor: Model: ❑Tank OverfilifRigh-level Sensor: Model• <br /> ❑Other,Spedfy equip. and model in Section E on Pae? Other S-Deci equip. and model in Section Eon Page 2 <br /> Dispenser M: ( Dispense c ID: <br /> [$Dispenser Containment Sensors: Model: 74 It W�%f ®Dispenser Conrainmeni Sensor(s): Model: W u3n 'fit <br /> Q Shear Valve(s). (2 Shear Valve(s), <br /> [7Dispenser Containment Float(s)and Chains D enter Containment Floats)and Chain(s) <br /> Dispenser ID: - v Dispenser ID.- 9-/o <br /> ®Dispcnscr Containment Sensors: Model: hk;o -1L( ( Dispenser Containment Sensor(s): Model <br /> Shear Valve(s). CM Shear Valve(s). <br /> ElDispeuser Containment Floats and Chain s ❑Dis enter Containment Float(s)and Cha s) <br /> Dispenser ID: S-,— Dispenser ID: II-ic- <br /> 2Dispenser Comainnent Sensors: Model, 1 �7Z,- i•+ ,�Diapenaer Containment Sensor(s). Model: 7� <br /> J2 Shen Valve(s), ® Shear Valve(s), <br /> j ❑Dis eraser Containment Float s' and Chain(s) Dia eager Containment Float(s)and Chain(s) <br /> *If the facility contains more tanks or dispensers,copy this fora. Include information for every tank and dispenser at this facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/scrviccd In accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. nranufactilMrs' checklists) aeaessary to verify that this information is <br /> correct and a Plot Plain showing the layout of monitoring equipment. For any equipment capable of generating,such reports,I have also <br /> attached a copy of the report;(check it that apply :, 'g System set-up Q Alarm history report <br /> Technician Name(Print): Sipanue: <br /> Certification No.: q).% License Nil: 588 098 <br /> Testing CompanyNarre: TAIT ENVIRONMENTAL SYSTEMS _ Phone No.: 1'714)560-3222 <br /> Page 1 of 3 03/01 <br /> Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.