My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006 - 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
COMPLIANCE INFO 2006 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2019 9:44:41 AM
Creation date
5/10/2019 4:24:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2011
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
382
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIARING SYSTEM CERTIF .,ATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited.• Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A se arate certificatio or each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provi t / erator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information APR 12 2011 <br /> Facility Name: Arco ENVIR0I f&:Ha4hT4_ <br /> Site Address: 1100 S. Main St. City: Manteca PERMIT/2WAM37 <br /> Facility Contact Person: Jessie Contact Phone No.: (209) 609-0117 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 3/31/2011 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the apgropriate boxes to indicate specific equipment inspected/serviced. <br /> Tank ID: T1: 87 Tank m: T2. 91 <br /> E In-Tank Gauging Probe. Model: 847390-109 E In-Tank Gauging Probe. Model: 847390-109 <br /> ®Annular Space or Vault Sensor. Model: 794390-409 E Annular Space or Vault Sensor. Model: 794390409 <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-323 E Piping Sump/Trench Sensor(s). Model: 794380-323 <br /> E Fill Sump Sensor(s). Model: 794380-323 E Fill Sump Sensor(s). Model: 794380-323 <br /> E Mechanical Line Leak Detector. Model: 99LD-2000 E Mechanical Line Leak Detector. Model: FE STP-MLD <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: T3' 89 Tank ID: <br /> E In-Tank Gauging Probe. Model: 847390-109 ❑In-Tank Gauging Probe. Model: <br /> E Annular Space or Vault Sensor. Model: 794390.409 ❑Annular Space or Vault Sensor. Model: <br /> E Piping Sump/Trench Sensor(s). Model: 794380-323 ❑Piping Sump/Trench Sensor(s). Model: <br /> E Fill Sump Sensor(s). Model: 794380-323 ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model: FE STP-MLD ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1&2 Dispenser ID: 3&4 <br /> E Dispenser Containment Sensor(s). Model: 794380-323 E Dispenser Containment Sensor(s). Model: 794380-323 <br /> ®Shear Valve(s). E Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5&6 Dispenser ID: 7&8 <br /> E Dispenser Containment Sensor(s). Model: 794380-323 E Dispenser Containment Sensor(s). Model: 794380-323 <br /> E Shear Valve(s). E Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9&10 Dispenser ID: 11&12 <br /> E Dispenser Containment Sensor(s). Model: 794380323 E Dispenser Containment Sensor(s). Model: 794380-323 <br /> E Shear Valve(s). E Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equi meat. For any equent capable of generating such <br /> reports,I have also attached a copy of the report;(check all that apply): IN i w <br /> System set-up Alarm histo report <br /> Technician Name(print): Guadalupe Sanchez _ Signa <br /> Certification No.: A30138 License.No.: 883706 <br /> Testing Company Name: Reliable Petroleum Services, Inc. Phone No.:(209) 845-8586 <br /> Testing Company Address: 11930 Horseshoe Rd. Oakdale, Ca.95361 Date of Testing/Servicing: 3/31/2011 <br /> Page 1 of 4 <br /> Rev(2/08) <br />
The URL can be used to link to this page
Your browser does not support the video tag.