My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
COMPLIANCE INFO 2010 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 11:22:26 AM
Creation date
5/13/2019 8:45:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2018
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN.JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.socehd.com <br /> UNDERGROUND STORAGE TANK UST PROGRAM INSPECTION REPORT <br /> Facility ` pp� Facility Inspection <br /> Name: Gj�ccc� �. 1 1V Phone: Date: 3 ks <br /> Facility CERS <br /> Address: ` ID: <br /> Inspection Title: Phone: <br /> Contact: �G�fj ,G �� �C�`i <br /> Inspection Program: <br /> Type: UGJ� L <br /> Congo5rit Given For: /� Consent <br /> spection �..P'hotos CfSa�mpling Given By: <br /> Service Tech Exp. Designated Exp. <br /> Onsite: Date: ^'j ( Operator. F - Date:'S l� <br /> Service Technician \ 3 All 3 17 <br /> Manufacturer's Training: W-1 — L — a 1 3 i 1 r— _ 31 <br /> CCR=California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat COS=Corrected on site during inspection <br /> File Review V R COS <br /> 101 HSC 25284 No permit to operate(V650) ❑ ❑ ❑ <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system(V735) ❑ ❑ ❑ <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted(V720) ❑ ❑ ❑ <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current(V651) ❑ ❑ ❑ <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan(V852) ❑ ❑ ❑ <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan(V853) ❑ ❑ ❑ <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed(V655) ❑ ❑ <br /> 108 CCR 2637(f), Failed to notify the EHD 48 hours prior to conducting testing(V671) ❑ ❑ ❑ <br /> 2638(e) <br /> 109 CCR 2637 Failed to test secondary containment(V660) ❑ ❑ ❑ <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days(V662) ❑ ❑ ❑ <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually(V659) ❑ ❑ ❑ <br /> 112 HSC 25284.2 Failed to test spill containers annually(V661) ❑ ❑ ❑ <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days(V823) ❑ ❑ ❑ <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down(V663) ❑ ❑ ❑ <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days(V658) ❑ Cl ❑ <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification(V848) ❑ ❑ ❑ <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after(V666) ❑ ❑ ❑ <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests(V667) ❑ 1 ❑ ❑ <br /> 119 HSC 25299 Documents were falsified or misrepresented(V657) ❑ ❑ ❑ <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification(V840) ❑ ❑ ❑ <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report(V804) ❑ ❑ ❑ <br /> 122 CCR 26310) Failure to submit UST system component statement of compatibility for substance stored(V721) ❑ ❑ ❑ <br /> On Site Records V R COS <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions(V725) ❑ ❑ ❑ <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years(V733) ❑ ❑ ❑ <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site(V732) ❑ ❑ ❑ <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site(V734) ❑ ❑ ❑ <br /> 205 CCR 2712(i) Failure to have an approved UST response plan available onsite(V654) ❑ ❑ ❑ <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions(V738) ❑ ❑ ❑ <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment(V737) ❑ ❑ ❑ <br /> ReceivedInspector: InspecPhone: �� <br /> By(initial): -n C>,•�c "fib D J <br /> EHD 23-01 REV 07/28/16 Page 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.