Laserfiche WebLink
the product overfilling[Section 2635(b)(2)(D)]. <br /> Manufacturer: Model: <br /> 7i PIPING INFORMATION <br /> 2 _ TANK# _ <br /> CLOSEST: 15'-4" CLOSEST: 15'-4" <br /> DISTANCEfrom FARTHEST. 85'-4" FARTHEST: 85'-4' <br /> DISPENSER to TANK <br /> WESTERN WESTERN <br /> MANUFACTURER FIBERGLASS FIBERGLASS <br /> CO—FLEX CO—FLEX <br /> TYPE*SYSTEM PIPE PIPE <br /> DOUBLE DOUBLE <br /> CONSTRUCTION WALL WALL <br /> MATPRIAI ** FRP I FRP <br /> VEEDER ROOT VEEDER ROOT <br /> LEAK DETECTION LINE LEAK LINE LEAK <br /> SYSTEM DETECTION DETECTION <br /> 100%COMPATIBILITY YES YES <br /> WITH METHANOL <br /> CORROSION YES YES <br /> PROTECTION <br /> * System Type: suction, pressure,and gravity <br /> ** Construction: single-walled,double-walled, lined-trench,etc. <br /> *** Material Type: steel with cathodic protection,stainless-steel,fiberglass reinforced plastic. <br /> 19. _,.�(_.- Piping(cross-sectional diagram,including connections to tank and dispensers). <br /> (A) Vent and tank riser primary containment system equipped with overfill prevention system that: <br /> X Restricts delivery of flow to tank[Section 2635(b)(2)(8)or(C)],or <br /> _X Provide positive shut off of flowto the tank at no more than 95%[Section 2635(b)(2)(C)],or <br /> (B) _N/A Vapor recovery piping designed so it cannot contain liquid phase product,or <br /> (C) �!LA Suction piping(below grade piping operates at less than atmospheric pressure)(Section 2636(a)(3)] <br /> Stoped so contents of the pipe will drain back into the storage tank if the suction is released. <br /> No valves or pumps installed below grade. <br /> Inspection method provided to demonstrate compliance with section 2636(a)(3). <br /> (D) ,( Corrodible underground piping protected against corrosion(Section 2636(b)). <br /> (E) Underground primary piping will meet all of the following requirements <br /> Primary pipingin contact with hazardous substance under nonnal operation conditions shall be: <br /> installed inside a secondary containment system in the form of:_secondary pipeVault or <br /> _lined trench to be sloped to a collection sump at the low point of the piping. <br /> Primary piping and secondary containment systems will be installed in accordance with industry <br /> code of practice and voluntary consensus standards.. <br /> NJA Lined trench used as secondary containment <br /> Material compatible with the substance stored. <br /> Covered and capable of supporting any expected vehicular traffic. <br /> (F) Underground piping with secondary containment will be equipped and monitored as follows: <br /> Secondary containment will be equipped with a continuous monitoring system connected to an <br /> audible and visual alarm system. <br /> 8 <br />