INSTALL 2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
INSTALL 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2019 11:34:29 AM
Creation date
5/15/2019 11:02:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2003
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Multiple tank installation will also require a <br />minimum of 12 inches between tank measured from <br />each. outside edge. <br />ANCHORING <br />7.0 Certain situations require the use of properly <br />desigaedanchor straps to overcome existing <br />buoyant forces. The straps are usedin conjunction <br />with a concrete holddown slab or deadman <br />anchors. <br />CAUTION: Use of steel cable: or round <br />bar is prohibited. <br />THE use OF STEEL <br />G u MOT um BAR <br />As NOLO 00" STRAPS <br />Is PROHIBITED <br />7.1 Apad of inert, insulating, dielectric material must <br />be used to separate the anchor strap from the <br />tank. <br />BACKFILL <br />8.0 Only the following approved backfill material may <br />be used. <br />1. Clean washed sand. <br />2. Pea Gravel - (particle size must be not less than <br />1/8 inch or more than 3/4 inch) <br />3. Washed stone or gravel crushings - <br />(angular particle size required to be not less <br />than 1/8 inch or more than 112 inch) <br />8.1 Special care should be used to ensure that the <br />backfill is properly installed to evenly support the <br />bottom quadrant of the tank. <br />NOTE: Do not backfill in layers using different <br />materials. <br />8.2 If tank must be ballasted during the backfill <br />procedure, at no time may the liquid exceed the <br />height of the compactedbackfill surrounding the <br />tank. <br />8.3 The tank shall be encompassedby the proper (. ' <br />beak£ill and extending to a minimum of 12. inches <br />over the top of.the tank. <br />SA Areas subject toheavy vehicular traffic shallhave <br />a.protective cover of 18 inches clean,compacted <br />soil with either 6 inches of reinforced concrete or S <br />inches of asphalt paving. If compactedsoil. is the <br />only cover; it shall be a minimum of 36 inches <br />deep. <br />8.5 Areas not subject to heavy vehicular traffic shall <br />have a protective cover of a minimum 18 inches of <br />clean compacted soil covered by flinches of <br />reinforced concrete or 6 inchesof asphalt paving. If <br />compacted soil is the only cover; it shall be a <br />minimum of 24 inches deep. <br />8.6 Finishing.Instructions; A.fiberglassingkitis <br />shipped with tank and provides: materials to cover <br />unused openings and external attachments, such <br />as lifting lugs. All finishing work will be done <br />prior to backfilling. <br />9.0 For Glasteal II warranty tobeinitiated, the <br />Installation Checklist must be properly filled out <br />by the customer, and returned to the Modern <br />Welding Co. subsidiary from which the tank was <br />fabricated. The Installation Checklist must be <br />returned within 30 days after date of installation. If the <br />Glasteel II tank has not been installed within 90. days <br />.of delivery from the manufacturer, it is required that the <br />tank be re -certified by the manufacturer, at the owner's /— <br />expense, prior to installation. (. <br />: MAINTENANCE <br />10.0 Maintenance of Underground Storage Tanks <br />The primary tank should be inspected monthly for the <br />presence of water. Inspections should take place at the. <br />lowest possible points inside the primary tank. Remove <br />any water found. Water and sedimentin fuel can cause - <br />plugging of filters. Also, bacterial growth originating from <br />the fuel, can cause filters to plug and corrosion of tanks <br />and lines. A report by the US Department of Energy, <br />BNL 48406, provides information on methods to test for <br />and remove water, test for bacterial presence in fuel, tank <br />cleaning and fuel additives. Failure to remove water from <br />the tank may void your warranty. <br />SUBSIDIARIES NATIONWIDE: <br />Corporate Of£ioe (270) 685-4400 <br />Modern Welding Company of Owensboro, Inc (270) 683-5323 <br />Modern Welding Company of Ohio, Inc (740) 344-9425 <br />Modern Welding Company of Florida, Inc (407) 843-1270 <br />Modern Welding Company of Texas, Inc (713) 675-4211 <br />Modern Welding Company of Texas, Inc (817) 636-2215 <br />Modern Welding Company of Iowa, Inc (319) 754-6577 <br />Modern Welding Company of California, Inc (209) 275-9353 <br />Modern Welding Company of Georgia, Inc (706) 722-3411 <br />