My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2019 5:10:41 PM
Creation date
5/15/2019 2:24:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
518
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FA0002409 PR0231211 SCO01 01/19/2017 <br />EHD 23-01 Rev. 09/22/16 Page 3 of 5 Underground Storage Tank Program OR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.ora/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Safeway Fuel Center#2707 <br />Facility Address: <br />6425 N PACIFIC AVE, STOCKTON <br />Date: <br />January 19, 2017 <br />UST System Observations <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />❑ V o R <br />❑ COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V ❑ R <br />❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R <br />❑ COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />o V ❑ R <br />❑ COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V o R <br />❑ COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />n V ❑ R <br />❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R <br />❑ COS <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R <br />❑ COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V ❑ R <br />❑ COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R <br />❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R <br />❑ COS <br />403 <br />CCR 2643(4) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R <br />❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R <br />❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R <br />❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R <br />❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V n R <br />❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />105 <br />CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. For all three underground storage tanks, <br />beneath Record Keeping, change "Yes" to "No' for Tank Integrity Testing Results.. The monitoring plan must be <br />uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS, make the <br />necessary changes, and submit for review by the EHD. <br />This is a minor violation. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations <br />where monitoring will be performed. The Site Plan does not indicate that there is a sensor in the submersible turbine <br />pump sump for 91 -product, and the fill sumps for 91-poduct and diesel product and that there is a sensor in the vent <br />sump. Also the leak detector locations are not included in the Plot Plan. Immediately log into the California <br />Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site <br />Plan. <br />This is a minor violation. <br />FA0002409 PR0231211 SCO01 01/19/2017 <br />EHD 23-01 Rev. 09/22/16 Page 3 of 5 Underground Storage Tank Program OR <br />
The URL can be used to link to this page
Your browser does not support the video tag.