My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2019 5:10:41 PM
Creation date
5/15/2019 2:24:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
518
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REGEIVEL <br />Monitoring System Equipment Certification FEB 19 2016 <br />For Use By All Jurisdictions Within The State of California C <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code ofR WRONMENTAL <br />14%I TU r=P4RTh/1FhIT <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br />prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br />to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br />within 30 days of test date. <br />A. General Information <br />Facility Name: Safeway Bldg. No.: <br />Site Address: 6425 N. Pacific Ave. City: Stockton, CA Zip: 95207 - <br />Facility Contact Person: Manager Contact Phone No.: (209) 472-8600 <br />Make/Model of Monitoring System: VR TLS -350 Date of Testing/Servicing: 1/20116 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Tank ID: 01-Rf190 <br />Tank ID• 02 -Prem <br />® <br />In- Tank Gauging Probe. <br />Model: <br />VR 947300.109 <br />11 <br />In- Tank Gauging Probe. <br />Model: <br />VR 847390,109, <br />® <br />Annular Space or Vault Sensor. <br />Model: <br />VR 7909MSO <br />® <br />Annular Space or Vault Sensor. <br />Model: <br />VR 79u9,0.4e0 <br />9 <br />Piping Sump\ Trench Sensor (a), <br />Model- <br />VR 7MOD-208 <br />® <br />Piping Sump Trench Sensor (a), <br />Model: <br />VR 794380,208 <br />® <br />Fill Sump Sensor (a), <br />Model: <br />VR 79,13110,2011 <br />® <br />Fill Sump Sensor (a). <br />Model: <br />VR 7%38w08 <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />® <br />Electronic Line Leak Detector. <br />Model: <br />VR soden 8480, <br />® <br />Electronic Line Leak Detector. <br />Model: <br />VR series 9884 <br />01 <br />Tank Overfill \ High -Level Sensor. <br />Model: <br />VR 7 90 0 91-0 01 <br />® <br />Tank Overfill \ High -Level Sensor. <br />Model: <br />vR 790091.001 <br />19 <br />Other ( specify equipment type and model in Section G on Page 2). <br />® <br />Other ( specify equipment type it model in Section E on Page 2). <br />Tank ID: 03 -Diesel <br />Tank ID: <br />® <br />In- Tank Gauging Probe. <br />Model: <br />VR847320-109 <br />❑ <br />In- Tank Gauging Probe. <br />Model: <br />® <br />Annular Space or Vault Sensor. <br />Model: <br />VR 794300-1i, <br />❑ <br />An polar Space or Vault Sensor. <br />Model: <br />® <br />Piping Sump\ Trench Sensor (s). <br />Model: <br />vR 794380.208 <br />❑ <br />Piping Sump\ Trench Sensor (s). <br />Model: <br />® <br />Fill Sump Sensor (a). <br />Model: <br />VR 794380-2011 <br />❑ <br />Fill Sump Sensor (s). <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />® <br />Electronic Line Leak Detector. <br />Model: <br />VR Series NU <br />❑ <br />Electronic Line Leak Detector. <br />Model: <br />- <br />• <br />Tank Overfill i High -Level Sensor. <br />Model: <br />IM790091-001 <br />❑ <br />Tank Overfill \ High -Level Sensor. <br />Model: <br />® <br />Other ( specify equipment type and model in Section E on Page 2). <br />❑ <br />Other ( specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 01-02 <br />Dispenser ID: 03.04 <br />® <br />Dispenser Containment Sensor (s). <br />Model: <br />VR 798380,209 <br />® <br />Dispenser Containment Sensor (a). <br />Model: <br />VR 7943aa20e <br />® <br />Shear valve (s). <br />0 <br />Shear Valve (s). <br />❑ <br />Dispenser Containment Float (s) and <br />Chain (s). <br />❑ <br />Dispenser Containment Float (s) and <br />Chain (s). <br />Dispenser ID: 05.06 <br />Dispenser ID: 07-08 <br />® <br />Dispenser Containment Sensor (a). <br />Model: <br />VR 794380.208 <br />9 <br />Dispenser Containment Sensor (s). <br />Model: <br />VR 798380,20/1 <br />® <br />Shear Valve (s). <br />R <br />Shear Valve (s). <br />❑ <br />Dispenser Containment Float (s) and <br />Chain (s). <br />❑ <br />Dispenser Containment Float (s) and <br />Chain (s). <br />Dispenser ID: 16.10 <br />Dispenser ID: 11-12 <br />no <br />Dispenser Containment Sensor (s). <br />Model: <br />VR794380.2011 <br />® <br />Dispenser Containment Sensor (a). <br />Model: <br />VR79439,a209 <br />® <br />Shear Valve (s). <br />® <br />Shear Valve (s). <br />❑ <br />Dispenser Containment Float (s) and Chain (s). <br />❑ <br />Dispenser Containment Float (s) and <br />Chain (s), <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturer's guidelines. Attached to this Certification is Information (e.g. manufactures' checklists ) necessary to verify that this <br />information is correct and a Plot Plan showing the layout of monitoring equipment. Far any equipment capable of generating such <br />reports, I have also attached a copy of the; (check all that apply): ❑ System set-up ❑ Alarm history <br />yrreport <br />Technician Name (print): Kris Bell Signature: <br />Mfg. Cert.#.: B33709 ICC# 5297793 -UT License. No.: 485184 <br />Testing Company Name: Service Station Systems Phone No.: (408) 971-2445 <br />Testing Company Address: 680 Quinn Ave., San Jose, CA 95112 Date of Testing/Servicing: 1120116 <br />
The URL can be used to link to this page
Your browser does not support the video tag.