My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2019 5:10:41 PM
Creation date
5/15/2019 2:24:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
518
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br />SEP 0 3 2015 <br />4. FILL RISER CONTAINMENT SUMP TESTING FnnnRnnin11 e19nlrnL <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ NF41TN ncoe13rs1'rA- <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specific) <br />Test Equipment Used: Incon Sump Tester Equipment Resolution: +/ 0,002" <br />Vent Sump <br />Sump Diameter: <br />18" <br />Sump Depth: <br />31" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />A.. <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />10.. <br />Condition of sump prior to <br />testing: <br />Good <br />Portion of Sump Tested <br />2" above piping <br />Sump Material: <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />30 minutes <br />Test Start Time: <br />10:00 am <br />Initial Reading (Rj): <br />5.5650 <br />Test End Time: <br />10:15 am <br />Final Reading (RF): <br />5.5664 <br />Test Duration: <br />15 min. <br />Chane in Reading (RF-Rj): <br />0.0014 <br />Pass/Fail Threshold or Criteria: <br />+1-0.00211 <br />Test Result: <br />© Pass ❑ Fail <br />Is there a sensor in the sump? <br />® Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑ Yes ❑ No ® NA <br />Wassensor removed for testing? <br />® Yes ❑ No C] NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />®yes ❑ No ❑ NA <br />Comments — (include information an repairs made prior to iesiing, and recommendedjbllow-up jar jailed rests) <br />Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work <br />
The URL can be used to link to this page
Your browser does not support the video tag.