COMPLIANCE INFO 2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2019 5:10:41 PM
Creation date
5/15/2019 2:24:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
518
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R CEI VEV <br />Monitoring System Equipment Certiflcat'O202015 <br />For Use By All Jurisdictions Within The .Stale of California �y <br />Authority Cited: Chapter 6.7, Health and Safely Code: Chapter 16, Division 3, Tale 23, California SN"'VIY� � <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or rega. otyi6�'ENIIAL <br />prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br />to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br />within 30 days of test date. <br />A. General Information <br />Facility Name: Safeway Bldg. No.: <br />Site Address: 6425 N. Pacific Ave. City: Stockton, CA Zip: 95207 - <br />Facility Contact Person: Manager Contact Phone No.: (209) 472-8600 <br />Make/Model of Monitoring System: VR TLS -350 Date of Testing/Servicing: 1122/15 <br />B. Inventory of Equipment Tested/Certified <br />.- t,..... ,. c,,..m, n..,inment iasnecmd/serelmd: <br />If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facilaN <br />C. Certification - [certify that the equipment identified in this document was inspected/serviced In accordance with the <br />manufacturer's guidelines. Attached to this Certification is information (e.g. manufactures' checklists ) necessary to verify that this <br />information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, 1 have also attached a copy ofthe: (cheek all that spplyl: ❑ Systemset-up ❑Q Alarm history report <br />Technician Name (print)• Randy Wilkerson Signature: LLL <br />Mfg. Cert.#.: A32404 ICC# 5258560 -UT License. No.: 485184 <br />Testing Company Name: Service Station Systems Phone No,:- (408)971-2445 <br />Testing Company Address: 680 Quinn Ave., San Jose, CA 96112 Date of Testing/Servicing: 1/22/15 <br />Tank ID•01-Regu <br />Tank ID• 02 -Prem <br />® <br />In- Tank Gauging Probe. <br />Model. <br />VR647390a109 <br />M <br />In- Tank Gauging Probe <br />Model: <br />VR &V390-109 <br />® <br />Annular Space or Vault Sensor <br />Mode;: <br />VR 7943110460 <br />® <br />Annular Space or Vault Sensor. <br />Model <br />VR 79439x460 <br />® <br />Piping Sump\ Trench Sensor (a). <br />Model: <br />VR 794380.208 <br />® <br />Piping Sump � Trench Sensor (a) <br />Model. <br />VR 794390.208 <br />® <br />Fill Sump Sensor (a). <br />Model. <br />VR7%38a208 <br />00 <br />Fill Sump Sensor is). <br />Model: <br />VR 784360409 <br />❑ <br />Mechanical Line Leak Detector. <br />Madel: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />M <br />Electronic Line Leak Detector. <br />Model <br />VR Sari,. 114114 <br />® <br />Electronic Line Leak Detector. <br />Model: <br />VR Senn 8484 <br />❑ <br />Tank Overfill l High-level Sensor. <br />Model: <br />VR790091.001 <br />❑ <br />Tank Oveifll\ High -Level Sensor. <br />Model: <br />VR 7WN14M <br />❑ <br />Other ( specify equipment type and <br />model in Section E on Page 2). <br />❑ <br />other ( specify equipment type and model in Section E on Page 2), <br />Tank Uh 03 -Diesel <br />Tank TD- <br />® <br />In -'rank Gauging PCObu. <br />Model: <br />VR 847390-109 <br />❑ <br />In - Tank Gauging Probe. <br />Model: <br />® <br />Annular Space or Vault Sensor. <br />Model: <br />VR 794390460 <br />❑ <br />Annular Space or Vault Sensor. <br />Model. <br />® <br />Piping Sump\ Trench Sensor (s). <br />Model. <br />VR 7119380208 <br />❑ <br />Piping Sump Trench Sensor (s). <br />Model: <br />® <br />Fill Sump Sensor (s). <br />Madel: <br />VR 7343110-2011 <br />❑ <br />Fill Sump Sensor (s) <br />Model; <br />❑ <br />Mechanical Line Leak Detector. <br />Model. <br />❑ <br />Mechanical Line Leak Detector. <br />Model <br />9 <br />Electronic Line Leak Detector, <br />Model: <br />VR 6adn 8434 <br />❑ <br />Electronic Line Leak Delecton <br />Model. <br />❑ <br />Tank Overfill \ High -Level Sensor. <br />Madel: <br />VR 79009 l <br />❑ <br />Tank Overfill \ High -Level Sensor <br />Model: <br />❑ <br />Other ( specify equipment type and model in Section E on Page 2). <br />❑ <br />Other ( specify equipment type tend model in Section E on Page 2). <br />Disppenser ID- 01.02 <br />Dispenser ID: 03.04 <br />It <br />Dispenser Containment Sensor (a). <br />Model: <br />VR 79438x208 <br />It <br />Dispenser Containment Sensor Is). <br />Model <br />VR 794080-20e <br />® <br />Shear Valve (s). <br />® <br />Shear Valve (s) <br />❑ <br />Dispenser Containment Float (s) and Chain (s). <br />❑ <br />Dispenser Contsmment Float (s) and Cham (s) <br />Dispenser ID: 06.06 <br />Dispenser IDS 07.08 <br />_ <br />0 <br />Dispenser Containment Sensor (s) <br />Madel <br />VR7N38a4o6 <br />CO <br />Dispenser Containment Senior (a). <br />Model: <br />VR 794"x2011 <br />® <br />Shear Valve (s). <br />M <br />Shear Valve (s). <br />❑ <br />Dispenser Containment Floats) and <br />Chain (s). <br />❑ <br />Dispenser Containment Float (a) and Chain (a), <br />Dispenser In, 08.10 <br />Dispenser ID- 11.12 <br />0 <br />Dispenser Containment Sensor (s) <br />Model. <br />VR794380,20e <br />® <br />Dispenser Containment Senior (s). <br />Model' <br />VR 794080408 <br />R <br />Shear Valve (s). <br />® <br />Shcar Valve (s). <br />Cl <br />Dispenser Containment Float (s) and Chain (s) <br />Cl <br />Dispenser Containment Float (s) and Chain (sl <br />If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facilaN <br />C. Certification - [certify that the equipment identified in this document was inspected/serviced In accordance with the <br />manufacturer's guidelines. Attached to this Certification is information (e.g. manufactures' checklists ) necessary to verify that this <br />information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, 1 have also attached a copy ofthe: (cheek all that spplyl: ❑ Systemset-up ❑Q Alarm history report <br />Technician Name (print)• Randy Wilkerson Signature: LLL <br />Mfg. Cert.#.: A32404 ICC# 5258560 -UT License. No.: 485184 <br />Testing Company Name: Service Station Systems Phone No,:- (408)971-2445 <br />Testing Company Address: 680 Quinn Ave., San Jose, CA 96112 Date of Testing/Servicing: 1/22/15 <br />