P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2019 5:10:41 PM
Creation date
5/15/2019 2:24:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
518
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JAN -30-2013 1051 Service Station Systems <br />10. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Ricer Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: C7 Sump Manufacturer ® industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum 0 Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Triton Sump Tester Equipment Resolution: +/- 0.002" <br />Fill Sump # 87 Fill Sump # 91 Fill Sump # Diesel Vent Sump <br />Sum2 Diameter: <br />42" <br />42" <br />42" <br />18" <br />Sump Depth: <br />81" <br />80" <br />81" <br />31" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />36" <br />34" <br />36" <br />8" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />34" <br />36" <br />32" <br />1011 <br />Condition of sump prior to <br />testing: <br />Good <br />Good <br />Good <br />OK <br />Portion of Sump Tested <br />2" above piping <br />2" above piping2" <br />above i in <br />Sum Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />stardri test: <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />10:03 am <br />9:25 am <br />8:55 am <br />lnitial Reading (Rl): <br />4.7999 <br />5.7470 <br />4.7139 <br />Test End Time: <br />10:18 am <br />9:41 am <br />9:10 am <br />Final Reading (Rr): <br />4.8001 <br />5.7470 <br />4.7131 <br />Test Duration: <br />15 min. <br />16 min. <br />15 min. <br />Chane in Reading %r-Rj): <br />0.0002 <br />None <br />0.0008 <br />Pass/Fail Threshold or Criteria: <br />+!- 0.002" <br />+/-0.002" <br />+/-0.002" <br />Test Result: <br />0 Pass Fail <br />0 Pass Fail <br />© Pass Fail <br />Pass M Fail <br />Is there a sensor in the sump? <br />0 Yes ❑ No <br />0 Yes Cl No <br />® Yes ❑ No <br />0 Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑ Yes ❑ No 0 NA <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />Was sensor removed for testing? <br />0 Yes Cl No ❑ NA <br />0 Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />❑ Yes ❑ No 0 NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />SYes ❑ No ❑ NA <br />❑Yes ❑ No 0 NA <br />on repairs made <br />Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work <br />Vent Sump Failed — Torn Boots, Penetration. <br />TOTAL P.10 <br />