m- � - <br />® Franklin Fueling Systems <br />Introducing the MagVFC <br />FE Petro would like to introduce its next <br />generation of Variable Frequency Controllers: the <br />MagVFC. In conjunction with the release of the <br />MagVFC, we have also introduced the MagShell <br />4 HP Variable Speed Pump Motor Assembly <br />(PMAMVS4), which is the first 4 HP pump motor <br />that fits into a 4" tank opening. <br />The MagVFC will also control the existing FE <br />Petro 2 Horsepower Variable Speed Pump Motor <br />Assembly (PMAVS2). When the VS4 (4 HP <br />Variable Speed Pump Motor) is being used the <br />MagVFC must be powered by 208/230V three <br />phase input voltage. If the MagVFC is used with a <br />2 HP Variable Speed Motor, it will operate on <br />single or three phase input power; however, two <br />horsepower performance will be slightly improved <br />if three phase input power is used. <br />The MagVFC continues to include the same <br />popular features as the IST-VFC with several <br />enhancements. Among these enhancements are: <br />• Fault Readout - When activated, the <br />MagVFC will display the last three fault <br />conditions encountered. <br />TECHNICAL BULLETIN <br />TBO18 <br />March 1, 2006 <br />7 -Segment <br />Displays <br />Silence <br />Button <br />Yellow Com. <br />LED <br />Reset Button <br />• Auto Restart from Underload (Dry Run) <br />Fault - When activated, the MagVFC will attempt to restart and automatically clear the fault on the next hook. <br />• Extended Run Protection - When activated, the MagVFC will shut the pump off if the pump runs for 60 minutes <br />with no change in pumping activity. <br />• Dual seven segment displays that indicate pump operating status and error codes and a yellow LED to indicate <br />communications activity. <br />• An audible alarm that indicates fault conditions, but also includes a silence button for acknowledging faults <br />without clearing them. <br />• Enhanced serial communication that allows intelligence sharing with INCON fuel management systems. <br />Compatibility of MagVFC and IST-VFC <br />• Like the IST-VFC, the MagVFC is only compatible with FE Petro model variable speed motors. <br />• Although the MagVFC can operate the VS4 and VS2 pump motors, the IST-VFC can only operate the VS2 <br />models. <br />• Starting in February of 2006, the MagVFC's communication protocols enable the controller to communicate with <br />the IST-VFC using a compatibility mode switch setting. This allows both controllers to function in Master/Slave <br />and Master/Slave Alternating Circuit configurations in cases where an IST-VFC is being replaced by a MagVFC. <br />This feature is only available on MagVFCs with a software revision of 1.18 or higher. <br />• Starting in October of 2003, FE Petro's Variable Frequency Controller, the IST-VFC, was replaced by the <br />MagVFC. <br />• Please refer to the MagVFC Installation and Owner's Manual for further details regarding installation and <br />operation of the MagVFC. <br />• Reference materials are available on our website. Please refer to Service Bulletin 011 and Technical Bulletin <br />T801 06-1 for further details on compatibility and communication settings. <br />Please contact Technical Support if we may be of any assistance. <br />Franklin Fueling Systems • 3760 Marsh Rd. • Madison WI 53718 USA <br />Tel: +1 608 838 8786 • 800 225 9787 • Fax: +1 608 838 6433 • www.franklinfueling.com <br />