Laserfiche WebLink
Monitoring System Equipment Certification <br />For Use By All Jurisdictions Within The Slate of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br />prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br />to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br />within 30 days of test date. <br />A. General Information <br />Facility <br />Bldg. <br />Site Address: 6425 N. Pacific Ave. City: Stockton, CA Zip: 95207 - <br />Facility Contact Person: Manager Contact Phone No.: (209) 472-8600 <br />Make/Model of Monitoring System: V/R TLS -350 Date of Testing/Servicing: 6/20/12 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Tank ID: 01-Regu <br />Tank ID: 02 -Prem <br />® <br />In- Tank Gauging Probe. <br />Model: <br />VR M7390-109 <br />® <br />In- Tank Gauging Probe. <br />Model: <br />VR847390409 <br />® <br />Annular Space or Vault Sensor. <br />Model: <br />vR 79090460 <br />® <br />Annular Space or Vault Sensor. <br />Model: <br />va794390480 <br />0 <br />Piping Sump \ Trench Sensor (s). <br />Model: <br />vR 79080-008 <br />® <br />Piping Sump \ Trench Sensor (s). <br />Model: <br />V!1794380-208 <br />III <br />Fill Sump Sensor (a). <br />Model: <br />va 794380-2ae <br />CO <br />Fill Sump Sensor (s). <br />Model: <br />VR waren-208 <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />® <br />Electronic Line Leak Detector. <br />Model: <br />VR renes UN <br />N <br />Electronic Line Leak Detector, <br />Model: <br />VR Santa. 804 <br />❑ <br />Tank Overfill \ High -Level Sensor. <br />Model: <br />❑ <br />Tank Overfill \ High -Level Sensor. <br />Model: <br />❑ <br />Other ( specify equipment type and model in Section E on Page 2). <br />❑ <br />Other ( specify equipment type and model in Section E on Page 2). <br />Tank II); 03 -Diesel <br />Tank ID: <br />M <br />In -Tank Gauging Probe, <br />Model: <br />VR U7390,1 Do <br />❑ <br />In - Tank Gauging Probe. <br />Model: <br />I& <br />Annular Space or Vault Sensor. <br />Model: <br />VR 79090460 <br />❑ <br />Annular Space or Vault Sensor. <br />Model: <br />® <br />Piping Sump \ Trench Sensor (s). <br />Model: <br />VR 794380-20 <br />❑ <br />Piping Sump \ Trench Sensor (s). <br />Model: <br />® <br />Fill Sump Sensor (s). <br />Model: <br />VR 794380-008 <br />❑ <br />Fill Sump Sensor (s). <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />Cl <br />Electronic Line Leak Detector. <br />Model: <br />VR Serie. Bda4 <br />❑ <br />Electronic Line Leak Detector. <br />Model: <br />❑ <br />Tank Overfill \ High -Levet Sensor. <br />Model: <br />❑ <br />Tank Overfill \ High -Level Sensor. <br />Model <br />❑ <br />Other ( specify equipment type and model in Section E on Page 2). <br />❑ <br />Other( specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 01.02 <br />Dispenser ID: 03.04 <br />® <br />Dispenser Containment Sensor (s). <br />Model: <br />VR 79080.208 <br />N <br />Dispenser Containment Sensor (s). <br />Model: <br />vR 764380-208 <br />® <br />Shear Valve (s). <br />0 <br />Shear Valve (s). <br />❑ <br />Dispenser Containment Float (s) and <br />Chain (s). <br />❑ <br />Dispenser Containment Float (s) and <br />Chain (s). <br />Dispenser ID: 05.06 <br />Dispenser 11)• 07-06 <br />® <br />Dispenser Containment Sencor(s). <br />Model: <br />VR 794380.209 <br />® <br />Dispenser Containment Sensor (s). <br />Model: <br />vR 794380.208 <br />® <br />Shear Valve (s). <br />N <br />Shear Valve (s). <br />❑ <br />Dispenser Containment Float (a) and <br />Chain (s). <br />❑ <br />Dispenser Containment Float (s) and <br />Chain (s). <br />Dispenser ID: 09.10 <br />Dispenser .. 11-12 <br />® <br />Dispenser Containment Sensor (a). <br />Model: <br />VR 794380-208 <br />E <br />Dispenser Containment Sensor (a), <br />Model: <br />VR 794380.208 <br />® <br />Shear Valve (s). <br />M <br />Shear Valve (s). <br />❑ <br />Dispenser Containment Float (s) and Chain (s). <br />❑ <br />Dispenser Containment Float (s) and Chain (s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility <br />C. Certification - I certify that the equipment identified In this document was Inspected/serviced in accordance with the <br />manufacturer's guidelines. Attached to this Certification is information (e.g. manufactures' checklists) necessary to verify that this <br />Information Is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, I have also attached a copy of the; (check all that apply); ❑ System set-up ❑ Alarm history report <br />Technician Name (pont): Myk® Briggs Signature:^7 /' <br />Mfg. Cert.#.: 838235 ICC# 8033115 -UT License. No.: 485184 <br />Testing Company Name: Service Station Systems Phone No.: (408) 971-2445 <br />Testing Company Address: 680 Quinn Ave., San Jose, CA 95112 Date of Testing/Servicing: 6/20112 <br />