My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2019 5:10:41 PM
Creation date
5/15/2019 2:24:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
518
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Equipment Certification <br /> For Use By All Jurisdictions Within The State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name:Safeway Bldg.No.: <br /> Site Address: 6425 N.Pacific Ave. City: Stockton,CA Zip: 96207- <br /> Facility Contact Person: Manager Contact Phone No.: (209)472.8600 <br /> Make/Model of Monitoring System: VR TLS-350 Date of Testing/Servicing: 2/23117 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: Tank ID: <br /> ❑ In-Tank Gauging Probe. Model. ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump\Trench Sensor(s). Model: ❑ Piping Sump\Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(a). Model: ❑ Fill Sump Sensor(a). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill\High-Level Sensor. Model: ❑ Tank Overfill\High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vagi Sensor, Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump\Trench Sensor(a). Model: ❑ Piping Sump\Trench Sensor(a). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector, Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill\High-Level Sensor. Model: ❑ Tank Overfill l High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section F on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2), <br /> Dispenser ID: 13.14 Dispenser ID: 18.16 <br /> ® Dispenser Containment Sensor(a). Model: VR 7943110-2118 0 Dispenser Containment Sensor(a). Model: VR 7043e0.208 <br /> ❑ Sheat-Valve(s), ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ tspenser Containment Sensor(a). Model: ❑ Dispenser Containment Sensor(a), Model: <br /> D Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(a). '.Model: ❑ Dispenser Containment Sensor(a). Model: <br /> ❑ Shmr Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> -if the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility <br /> C.Certification- I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturer's guidelines. Attached to this Certincation Is information(ag.monuhctures'checklists)necessary to verity that this <br /> Information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the; (cbeckall tkarapply): ® System set-up 0 .Alarm history report <br /> Technician Name(printi: Randy Wilkerson Signature: it 6-441 <br /> Mfg.Cert.#.: A32404 ICC# 5268560-UT License.No.: 486184 <br /> Testing Company Name: Service Station Systems Phone No.: (408)971-2445 <br /> Testing Company Address: 680 Quinn Ave.,San Jos 6I esting/Servicing: 2/23/17 <br /> Y <br /> E. tysry <br /> MAR 2 3 2017 <br /> ENVIRONMENTAL HEALTH <br /> l�Cr)oQThn- <br />
The URL can be used to link to this page
Your browser does not support the video tag.