Laserfiche WebLink
The FID will be calibrated for benzene. Total organic vapor readings will be used to <br />determine the appropriate levels of respiratory protection for conditions at the site. Total <br />organic vapor concentrations in the worker breathing zone greater than 10 ppm above <br />background will trigger an upgrade from level D to level C protection. Breathing zone <br />concentrations greater than 250 ppm will stop the work until the work zone <br />concentrations are reduced to below 250 ppm. <br />EMPLOYEE TRAINING AND INFORMATION <br />All personnel working on site must have completed the certified 40 hour OSHA hazardous <br />waste training course, and be trained in the following objectives: <br />Worker awareness of potential hazards they may encounter. <br />Knowledge and skills necessary to perform the work with minimal risks to <br />workers health and safety. <br />Familiarization with the Site Safety plan and site specific requirements. <br />The training plan for this site encompasses: <br />Potential physical and chemical health hazards. <br />Respiratory protection, rationale, use, maintenance and fit testing. <br />Protective clothing, use and maintenance. <br />Entry, exit and decontamination procedures. <br />— Documentation and record keeping procedures. <br />KEY PERSONNEL <br />Client Contact: <br />Governmental Contact: <br />Site Safety Officer: <br />Alternate Site Safety Officer: <br />