i=i �■��r�■i �■i iw�wa n■�� err � +>�r � �■� � � ISE �■1 r•I �: �
<br /> TABLE I (Cont.)
<br /> EVAX TECHNOLOGIES, INC.
<br /> EXTRACTION DELL/PROBE SUMMARY
<br /> SITE. Beacon Station 0695 Incinerator Start Up: 18 July 1991
<br /> 900 Swth Cherokee Lane
<br /> Lodi, California
<br /> MW-1 MW-2 MW-3 MW-4 MW-5 MW-6
<br /> DATE TVH VP TVH VP TVH VP TVH VP TVH VP TVH VP
<br /> ------••------------------------------------------------------------------------------- .............................
<br /> 09/22/92 1,800 FO 0 10 C 6,000 0 300 C 260 0 2,600 0
<br /> 09/08/92 4,000 FO 0 5 C 9,000 0 30 C 425 0 6,000 0
<br /> 08/26/92 5,000 0 20 C 10,000+ 0 70 C 700 0 10,000+ 0
<br /> 08/13/92 10,000+ 0 10 C 15,000 0 475 0 600 0 10,000 0
<br /> 07/28/92 4,000 FO 0 10 C 7,000 0 640 0 640 0 6,400 0
<br /> 07/17/92 10,000+ 0 H2O C 101000+ 0 400 0 700 0 10,000+ 0
<br /> 07/01/92 9,300 0 H2O C 10,000+ 0 350 0 600 0 10,000+ 0
<br /> 06/16/92 700+ 0 H2O C 10,000+ 0 ND C 100 0 6,000+ 0
<br /> 06/03/92 7,980 GC 0 H2O C 6,000 O 20 C 7 C 10,000 0
<br /> 05/20/92 3,200 0 H2O C 4,500 0 5 C 30 C 4,700 FO 0
<br /> . 05/06/92 16,400 0 H2O C 9,000 0 10 C 25 C 10,000 FO 0
<br /> 04/22/92 15,120 0 H2O C 400 0 40 C 2 C 1,050 0
<br /> 04/17/92 2,000 FO 0 H2O C 10 C 15 C 17 C 70 C
<br /> 04/10/92 4,000 FO 0 H2O C 4,000 FO 0 ND C 50 FO C 2,000 FO O
<br /> 01/22/92 70 C H2O C 520 0 ND C H2O C 3,400 0
<br /> 12/23/91 6,600 0 H2O C 8,800 0 820 0 44 C 8,000 0
<br /> 12/10/91 95+ 0 H2O C 1,850 0 55 0 H2O C 90 0
<br /> 11/27/91 35+ 0 H2O C 650 0 HT 0 1,150 0 1,250 0
<br /> 11/01/91 10,000+ 0 ND C 6,000+ 0 2,500 0 5,000 0 10,000+ 0
<br /> 10/15/91 10,000+ 0 30 C 1,200 0 850 0 30000 0 5,400 0
<br /> 7/31/91 820 0 18,000 0 18,000 0 14,000 0 16,000 0 10,000 0
<br /> 7/18/91 780 C 20,000 0 20,000 0 20,000 0 20,000 0 600 C
<br /> INTERVAL (DIA) 38 - 558 (2") 4 - 20+ (211) 4 - 201 (211) 4 - 201 (211) 4 - 20' (211) 4 - 201 (20)
<br /> EXTRACTION POINT - Extraction probe/well identification as indicated on site pian
<br /> INTERVAL - Screened interval or perforated range of well or probe in feet below grade. Well/probe diameter in inches.
<br /> TVH - Total volatile hydrocarbons in parts per million (ppm) on a volume/volume basis.
<br /> VP - Manifold valve position. (0=open) (C=Closed) _
<br /> H2O Water in Extraction Line.
<br /> FO - FID Flame Out, generally due to high concentrations and lou oxygen.
<br /> VP.1 - Vapor probes t
<br /> MW - Monitoring well
<br />
|