TABLE i (Cont )
<br /> EVAX TECHNOLOGIES, INC.
<br /> EXTRACTION YELL/PROBE SUMMARY
<br /> r
<br /> SiTE- Beacon station #695 incinerator Start Up: 18 July 1991
<br /> 900 South Cherokee Lane
<br /> Lodi, California
<br /> NW-17 FSU-22 NW-27 VU-26 RW-1
<br /> DATE INSTR TVH VP TVH VP TVH VP TVH VP TVH VP
<br /> ------------------ --------------- ............................................ .
<br /> 09/22/92 OVA 1,200 0 175 0 6,800 0 200 0 3,000 0
<br /> 09/08/92 OVA 220 0 175 FO 0 10,000+ 0 300 0 5,000 0
<br /> 08/26/92 OVA 4,000 0 120 0 10,000+ 0 400 0 10,000+ 0
<br /> 08/13/92 OVA 6,000 0 600 0 10,000* 0 450 0 3,200 GC 0
<br /> 07/28/92 OVA 3,600 0 100 FO 0 8,200 0 1,300 0 180 0
<br /> 07/17/92 OVA 10,000+ 0 52 0 10,000+ 0 850 0 10 C
<br /> 07/01/92 OVA 8,800 0 200 0 10,000+ O 1,950 0 25 C
<br /> 06/16/92 OVA 6,000+ 0 20 0 10,000+ 0 1,000 0 ND C
<br /> 06/03/92 OVA 3,750 0 15 C 13,000 0 450 0 45 C
<br /> 05/20/92 OVA 1,980 0 20 C 10,800 0 850 0 88 C
<br /> 05/06/92 OVA 9,200 0 5 C 12,000 0 800 0 200 C
<br /> 04/22/92 OVA 8,400 0 7 C 4,630 0 500 0 ND C
<br /> 04/17/92 OVA 3,000+ 0 10 C 10,00040 0 NA C 30 C
<br /> 04/10/92 OVA 4,000 FO 0 15 C 10,000+ 0 550 C 30 C
<br /> 01/22/92 FID 480 0 2 C 5,800 0 H2O C LEAK C
<br /> 12/23/91 TLV 7,200 0 4,000 0 10,000+ 0 H2O C 130 C
<br /> 12/10/91 FID 250 0 80+ 0 10,000+ 0 H2O C 2 C
<br /> 11/27/91 FID 3,200+ 0 FO 0 2,350 0 H2O C No C
<br /> 11/01/91 OVA 10,000+ 0 10,000+ 0 10,000+ 0 300 C ND C
<br /> 10/15/91 FiD 3,500 0 80 0 10,000+ 0 620 0 10,000+ 0
<br /> 7/31/91 TLV 1,000 0 6,600 0 420 0 7,800 0 1,300 0
<br /> 7/18/91 TLV 900 C 1,200 C 15,000 0 8,000 0 7,000
<br /> INTERVAL (DIA) 46 - 701 (211) 46 - 701 (NA) 42 - 70' (211) 29 - 59' (29 33 - 80' 211 7p
<br /> EXTRACTION POINT - Extraction prone/well identification as indicated on site plan. U
<br /> INTERVAL - screened interval or perforated range of well or probe in feet below grade. Nell/probe diameter in Inches.
<br /> TVH - Total volatile hydrocarbons in parts per million (ppm) on a volume/volume basis.
<br /> VP - Manifold valve position. (O=Open) (C=Closed)
<br /> TLV - Threshold Limit Values meter detects combustible gases by oxidation using a hexene standard.
<br /> FID - Portable hydrocarbon monitor equipped with a Flame Ionization Detector
<br /> OVA - Foxboro Organic Vapor Analyzer equipped with a Flame Ionization Detector
<br /> FO - FID Flame Out, generally due to high concentrations and tow oxygen. i
<br /> H2O - Water in Extraction Line.
<br /> I
<br />
|