EVAX TECHNOLOGIES, INC
<br /> SYSTEM KONITORING SUMMARY
<br /> 500 SCFM CATALYTIC INCINERATOR
<br /> SITE: Beacon Station 0695 Incinerator Start Up. 18 July 1991
<br /> 900 South Cherokee Lane
<br /> Lodi, California
<br /> EXTRACTIMI WELL SUMMARY
<br /> EXTRACTION POINT
<br /> GW-7 MW-8 �zj-9 NW-10 MW-15 NW-16
<br /> DATE TVH VP TVH VP TVH VP TVH VP TVH VP TVH VP
<br /> ---------------------------------------------------------------------------------------------------------------------
<br /> 01/22/92 H2O C 9,200 0 580 0 10,000+ 0 H2O C 2 C
<br /> 12/23/91 240 C 10,000+ 0 2,400 0 10,000+ 0 H2O C 1,200 C
<br /> 12/10/91 H2O C 20+ 0 1,500 0 8,450 0 H2O C 38 C
<br /> 11/27/91 H2O C 2,380 0 320 0 1,500 0 90 C 50 C
<br /> 11/01/91 350 C 10,000+ 0 1,000 0 10,000+ 0 500 C 5 C
<br /> 10/15/91 2,000 0 NT 0 14,000 0 8,600 0 420 0 82 C
<br /> 7/31/91 10,040 0 16,000 0 8,500 0 660 0 7,400 0 6,200 0
<br /> 7/18/91 10,000 0 15,000 0 8,800 0 10,000 0 8,000 0 6,800 0
<br /> Nil-17 W-22 NW-25 MW-26 RW-1
<br /> --DATE- INSTR TVH VP TVH VP TVH VP TVH VP TVH VP
<br /> ----------------------------------------------------------------------------------------
<br /> 01/22/92 FID 480 0 2 C 5,800 0 H2O C LEAK C
<br /> 12/23/91 TLV 7,200 0 4,000 0 10,000+ 0 H2O C 130 C
<br /> 12/10/91 FID 250 0 804 0 10,000+ 0 H2O C 2 C
<br /> 11/27/91 FID 3,200+ 0 FO 0 2,350 0 H2O C ND C
<br /> 11/01/91 OVA 10,000+ 0 10,0004 0 10,000+ 0 300 C ND C
<br /> 10/15/91 FID 3,500 0 80 0 10,000+ 0 620 0 10,000+ 0
<br /> 7/31/91 TLV 1,000 0 6,600 0 420 0 7,800 0 1,300 0
<br /> 7/18/91 TLV 900 C 1,200 C 15,000 0 8,000 0 7,000 0
<br /> I
<br /> EXTRACTION POINT - Extraction probe/welt identification as indicated on site plan
<br /> TVH - Total volatile hydrocarbons in parts per oillion (ppm) on a volume/volume basis.
<br /> VP - Manifold valve position. (O=Open) (C=Closed)
<br /> TLV - Threshold Limit Values meter detects combustible gases by oxidation using a hexane standard
<br /> FID - Portable hydrocarbon monitor equipped with a Flema ionization Detector
<br /> OVA - Foxboro Organic Vapor Analyzer equipped faith a Flame ionization Detector
<br /> FO - FID Flame Out, generally due to high concentrations and low oxygen
<br /> H2O - Water in Extraction Line
<br />
|