My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
2235
>
3500 - Local Oversight Program
>
PR0544496
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 11:44:02 AM
Creation date
5/28/2019 11:36:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0544496
PE
3528
FACILITY_ID
FA0005409
FACILITY_NAME
LARGINS SERVICE
STREET_NUMBER
2235
STREET_NAME
CHEROKEE
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
11924017
CURRENT_STATUS
02
SITE_LOCATION
2235 CHEROKEE RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FGL Environmental Doe ID: SOQA105.001 <br /> Revision Date: 5/7/96 Page:2 of 3 <br /> 5.1-3 Verify that all standard codes for prep and analysis are listed with volumes where necessary. <br /> 5.2 Calibration Data Review <br /> 5.2.1 Verify that the proper calibration parameters were performed and requirements met as stated <br /> in the SOP for the test. <br /> 5.2.2 For calibrations that are not performed with each analytical run,the valid calibration needs to <br /> be documented in the FGL's calibration curve binder located in each department. <br /> 5.3 Analysis Quality Control Review <br /> 5.3.1 Each analysis batch is of proper size according to the method or as specified in the SOP. <br /> 5.3.2 Initial Calibration Verification (ICV) / Continuing Calibration Verification (CCV) - if <br /> applicable,the ICV needs to be performed immediately after calibration and before samples. <br /> The CCV must be performed at the method specified interval and at the end of the run. The <br /> recovery must fall within the method specified limit. <br /> 5.3.33 Initial Calibration Blank(ICB)/Continuing Calibration Blank(CCB)-if applicable,the ICB <br /> needs to be performed immediately after the ICV and before samples. The CCB must be <br /> performed at the method specific interval (after each CCV) and at the end of the run. The <br /> result must be less than the DLR <br /> 5.3.4 Internal Standard (IS) - if applicable, the IS needs to be performed with all analyses. The <br /> recovery must fall within the method specified limit. <br /> 5.4 Sample Preparation/Matrix Quality Control Review <br /> 5.4.1 Verify the yr ne batch is of proper size according to the method or as specified in the SOP. <br /> 5.4.2 Surrogate Spike(SS)-if applicable,the SS needs to be spiked into all samples going through <br /> the preparation process. The recovery must fall within the method specified limit. <br /> 5.4.3 Preparation Blank(PB)-the PB must be less than FGL's method specified DLR <br /> 5.4.4 Laboratory Control Sample (LCS) - the LCS recovery should be within the statistical <br /> acceptance range(AR%)and must be within the EPA method limit. <br /> 5.4.5 Matrix Spike Sample(MS)/Blank Spike(BS) -the recovery for the spiked sample or blank <br /> should be within FGL's statistical acceptance range (ARO/6). Confirm the spike level and <br /> analysis if the recovery is out of limit. <br /> 5.4.6 Duplicates Samples-the relative percent different(%Diff)between the MS/MSD,BS/BSD <br /> or sample and sample duplicate should less than the FGL's statistical Maximum Acceptable <br /> Value(%MAV). <br />
The URL can be used to link to this page
Your browser does not support the video tag.