My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FITE
>
4704
>
2800 - Aboveground Petroleum Storage Program
>
PR0527397
>
COMPLIANCE INFO_
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2019 4:31:56 PM
Creation date
5/28/2019 1:02:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0527397
PE
2832
FACILITY_ID
FA0014693
FACILITY_NAME
MARTIN-BROWER CO
STREET_NUMBER
4704
STREET_NAME
FITE
STREET_TYPE
CT
City
STOCKTON
Zip
95215
APN
18111013
CURRENT_STATUS
01
SITE_LOCATION
4704 FITE CT
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 1 O A O U IN Environmental Health Department <br /> - OU V 11•— <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Atltlress: Dale: <br /> MARTIN-BROVJER CO 4704 FITE CT, STOCKTON Apr <br /> i130, 2019 <br /> Other Violations <br /> 4020 See below unlisted Training violation o v DR o COS <br /> 4030 See below Unnstee operations/maintenance violation EV DR o cos <br /> 4040 See below Unllstetl Release/Leaksl5pills violation DR DR o COS <br /> 4D5o See below Unlisted Abandonmentillegal Disposal/Unauthorized Treatment violation Do o R (,COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item 4 Remarks <br /> 301 CFR 112.5(a)Failed to amend Plan as necessary. <br /> Three generators, each with 1,026 gallon belly tanks storing diesel were observed at the facility and are not addressed <br /> In the SPCC plan. Per facility personnel,the generator belly tanks may have been storing the diesel for over six months. <br /> The Me 10,000 gallon diesel tanks appear to be permanently manifolded and this is not addressed in the SPCC plan. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan must be amended when there is a change in the <br /> facility design, construction, operation,or maintenance that materially affects its potential for a discharge,within 6 <br /> months of the change, and implemented as soon as possible, not later than 6 months following preparation of the <br /> amendment.The SPCC Plan should accurately represent the procedures and policies currently in place at the facility, <br /> TAc e- acokli wktL 3c Aaau t. eltk- ?4.1 . ErA - 6-30- 11 of. ZwAlkl <br /> Note'. Permanently manifolded tanks are tanks that are designed, installed, or operated in such a manner that the <br /> multiple containers function as a single storage unit(67 FR 47122, July 17, 2002).Accordingly, the total capacity of <br /> manifolded containers is the design capacity standard for the sized secondary containment provisions(plus freeboard <br /> in certain cases). .5 TLG ?eller LAP,LL $e Am,eigai ^- ETA - L•Se• 14 at Saavet <br /> This is a repeat violation, Class II. <br /> 618 CFR 112.7(e), 112.8(c)(6) Failed to keep records cf procedures, inspections,or Integrity tests for three years. <br /> The SPCC plan calls for annual inspections of the tanks per Steel Tank Institute(STI)SP-001 standard.The annual <br /> inspections are not being conducted on any of the tanks, as required by the STI SP-001 standard. Inspections and <br /> testing shall be conducted on all aboveground liquid petroleum containers larger than 55 gallons, including all 55 gallon <br /> drums of oil. Conduct inspections and tests required by this part in accordance with written procedures that you or the <br /> certifying engineer develop for the facility. You must keep these written procedures and a record of the inspections and <br /> tests,signed by the appropriate supervisor or inspector,with the SPCC Plan for a period of three years. Records of <br /> inspections and tests kept under usual and customary business practices will suffice for purposes of this paragraph. <br /> Immediately begin necessary testing and inspections for all Aboveground Petroleum Storage Act regulated containers <br /> and maintain on sitewith the SPCC Plan. T66 Aam..+L LNaga•c14-d �hres sew <br /> 7w— tA <br /> CowJ[�M <br /> This into repeat violation,Class ll, J WILL � tuwe r-k- e- S y"As <br /> FAoot4&90 PR0527397 an001 aa(Jmzoie <br /> EHD20-01 rev 091 page 4 of Adwa9mund Pelmleum Ownwe Ad 01R <br /> 1868 E Hazelton Avenue I Stockton, California 952051 T 209 488-34201 F 209 464-0138 1 www Ocehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.