Laserfiche WebLink
Case Closure Summary <br /> Leaking Underground Fuel Storage Tank Program <br /> I.Aqency Information <br /> Agency Name: San Joaquin County Environmental Health Department(EHD) Address: 1868 E. Hazelton Avenue <br /> City/State/Zip: Stockton, CA 95205 Phone: (209)468-3436 <br /> Responsible Staff Person: Nuel Henderson Title: Engineering Geologist <br /> II. Case Information <br /> Site Facility Name: Cherokee Trucking <br /> Site Facility Address: 3535 Cherokee Road, Stockton, CA 95205 <br /> RB LUSTIS Case No: 390223 Local/LOP Case No: 1800 Sweeps No: URF Filing Date: 5/3/1988, 8/3/1988, <br /> 4/7/1989, 8/22/1989, 10/5/1989, 12/4/1989, 4/7/1995, 4/10/1995 <br /> Responsible Parties Addresses Phone Numbers <br /> Delta Fleet Service(reported to be defunct) PO Box 8968, Stockton, CA 95208 <br /> Delta Truck Sales(reported to be defunct) PO Box 8968, Stockton, CA 95208 <br /> Cecchini, Cecchini and Giovanni. 3000 E. 18`"Street, Ste 18, Antioch, CA, 94509 (925) 754-2058 <br /> Tank# Size (gallons) Contents Closed In-Place/Removed Date <br /> 39-1800-01 8,000-gallon, steel Diesel Removed 9/18/1997 <br /> 39-1800-02 8,000-gallon, steel Gasoline Removed 9/18/1997 <br /> 39-1800-03 10,000-gallon, steel Diesel Removed 9/18/1997 <br /> 39-1800-04 10,000-gallon, steel Diesel Removed 9/18/1997 <br /> 39-1800-05 7,500-gallon, steel Gasoline Removed 9/18/1997 <br /> 39-1800-06 2,000-gallon, steel Gasoline Removed 9/18/1997 <br /> 39-1800-07 2,000-gallon, steel Waste Oil Removed 10/5/1989 <br /> 39-1800-08 500-gallon, steel Motor Oil Removed 10/5/1989 <br /> 39-1800-09 500-gallon, steel Motor Oil Removed 10/5/1989 <br /> 39-1800-10 500-gallon, steel Waste Oil Removed 10/5/1989 <br /> Regarding tank sizes and contents see Section VII comments <br /> III. Release and Site Characterization Information <br /> Cause and Type of Release: Unknown. <br /> Site Characterization Complete? Yes Date Approved by Oversight Agency: 10/26/2010 <br /> Monitoring Wells Installed?Yes Number: 13 total; 9 MWs, 1 VP and 3 Properly Screened?Yes <br /> SVEs <br /> High GW Depth(btc): DTW=45.57 feet(MW-4 Low GW Depth: DTW= 83.60 feet(MW- Gradient: 0.001-0.007 <br /> on 03/20/2000) 1 on 09/25/1990) 1 generallytoward the NE <br /> Most Sensitive Current Use: Potential beneficial Are Drinking Water Wells Affected? No <br /> Aquifer Name: San Joaquin River Basin. Is Surface Water Affected? No. Nearest Surface Water: Stockton Diversion <br /> Canal -2,300 feet SSW <br /> Off-site Beneficial Use Impacts (Address/Locations): None. Report(s) are on file with: EHD and GeoTracker <br />