My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0001900
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
3535
>
3500 - Local Oversight Program
>
PR0544497
>
ARCHIVED REPORTS XR0001900
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 3:33:07 PM
Creation date
5/28/2019 2:55:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0001900
RECORD_ID
PR0544497
PE
3528
FACILITY_ID
FA0003687
FACILITY_NAME
OLD TRUCK STOP, THE
STREET_NUMBER
3535
STREET_NAME
CHEROKEE
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
13206009
CURRENT_STATUS
02
SITE_LOCATION
3535 CHEROKEE RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SolaC'nster Laboratories <br /> z�SiHd��ie•i � Explanation of Symbols and Abbreviations <br /> llowing defines common symbols and abbreviations used in reporting technical data <br /> N D none detected BMQL Below Minimum Quantitation Level <br /> TNTC Too Numerous To Count MPN Most Probable Number <br /> IU International Units CP Units cobalt-chloroplatinate units <br /> umhoslem micromhoslcm NTU nephelometric turbidity units <br /> C degrees Celsius F degrees Fahrenheit <br /> meq mihequivalents lb. pound(s) <br /> g gram(s) kg kilogram(s) <br /> ug microgram(s) mg milligram(s) <br /> ml milliliter(s) I liter(s) <br /> m3 cubic meter(s) ul microliter(s) <br /> < less than-The number following the sign is the limit of guaribtation,the smallest amount of analyte which can be <br /> reliably determined using this specific test <br /> > greater than <br /> J estimated value—The result is z,the Method Detection Limit(MDL)and<the Limit of Quantitation(LOQ) <br /> PPM parts per million-One ppm is equivalent to one milligram per kilogram(mglkg),or one gram per million grams For <br /> aqueous liquids,ppm is usually taken to be equivalent to milligrams per liter(mgll),because one liter of water has a <br /> weight very close to a kilogram For gases or vapors,one ppm is equivalent to one microliter of gas per liter of gas <br /> ppb parts per billion <br /> Dry weight Results printed under this heading have been adjusted for moisture content This Increases the analyte weight <br /> basis concentration to approximate the value present in a similar sample without moisture All other results are reported <br /> on an as-received basis <br /> EPA CLP Data Qualifiers <br /> Organic Qualifiers Inorganic Qualifiers <br /> A TIC is a possible aldol-condensation product B Value is<CRDL, but zIDL. <br /> B Analyte was also detected in the blank E Estimated due to interference <br /> C Pesh ade result confirmed by GC/MS M Duplicate injection precision not met <br /> D Compound quantitated on a diluted sample N Spike sample not within control limits <br /> E Concentration exceeds the calibration range of S Method of standard additions(MSA)used <br /> the instrument for calculation <br /> N Presumptive evidence of a compound (TICs only) U Compound was not detected <br /> P Concentration difference between primary and W Post digestion spike out of control limits <br /> confirmation columns>25% Duplicate analysis not within control limits <br /> U Compound was not detected + Correlation coefficient for MSA<0 995 <br /> X,Y,Z Defined in case narrative <br /> Analytical test results for methods listed on the laboratones'accreditation scope meet all requirements of NELAC unless <br /> otherwise noted under the individual analysis <br /> Measurement uncertainty values,as applicable, are available upon request <br /> Tests results relate only to the sample tested Clients should be aware that a critical step in a chemical or microbiological <br /> analysis is the collection of the sample Unless the sample analyzed is truly representative of the bulk of matenal Involved,the <br /> test results will be meaningless if you have questions regarding the proper techniques of collecting samples, please contact <br /> us We cannot be held responsible for sample Integrity,however, unless sampling has been performed by a member of our <br /> staff This report shall not be reproduced except in fuli,without the written approval of the laboratory <br /> WARRANTY AND LIMITS OF LIABILITY-In accepting analytical work,we warrant the accuracy of test results for the sample as submitted <br /> THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES,EXPRESSED OR <br /> IMPLIED WE DISCLAIM ANY OTHER WARRANTIES,EXPRESSED OR IMPLIED,INCLUDING A WARRANTY OF FITNESS FOR <br /> PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE <br /> FOR INDIRECT,SPECIAL,CONSEQUENTIAL,OR INCIDENTAL DAMAGES INCLUDING,BUT NOT LIMITED TO, DAMAGES FOR LOSS <br /> OF PROFIT OR GOODWILL REGARDLESS OF(A)THE NEGLIGENCE(EITHER SOLE OR CONCURRENT)OF LANCASTER <br /> ORATORIES AND(B)WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH <br /> *AGES We accept no legal responsibility for the purposes for which the client uses the test results No purchase order or other order <br /> ork shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of <br /> Lancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client <br /> 376802 <br />
The URL can be used to link to this page
Your browser does not support the video tag.