Laserfiche WebLink
%W <br /> 22 February 2010 <br /> AGE-NC Project No. 96-0235 <br /> Page 7 of 7 <br /> 40-m1 volatile organic analysis (VOA) vials and amber 1-liter bottles without preservative. <br /> Following collection, samples will be placed on ice and kept in a cooler until delivered to the <br /> laboratory for analysis.Chain-of-custody protocols will be used to document sample custody transfer <br /> from the field to the analytical laboratory. A chain-of-custody form will accompany the samples. <br /> 3.5. EQUIPMENT DECONTAMINATION/WASTE MANAGEMENT <br /> All sampling tools used for sample collection, except for disposable bailers, will be thoroughly <br /> rinsed with clean water after being washed with a solution of Alconox. All down-hole drilling <br /> equipment will be pressure washed prior to starting each boring. Cuttings generated during drilling <br /> and rinseate generated during drilling and ground water sampling activities will be containerized in <br /> properly labeled DOT-approved 55-gallon. <br /> Advanced GeoEnviron mental,Inc. <br />