Laserfiche WebLink
Historical Background Information: West Clay Properties <br /> Page 6 of 7 <br /> pressures. <br /> Hydrogeologic Unit 5 (HU5) extends from a minimum depth of 166 feet bsg to approximately 191 <br /> feet bsg; HU5 is composed primarily of coarse-grained soils including sand and gravelly sand <br /> interbedded with minor silt and clayey silt and silt. HU5 is characterized by generally low pore <br /> pressures, and may be classified as a flow unit. HU5 was observed in borings CPT-03 and CPT-04 <br /> and appears to be laterally continuous beneath the site. <br /> Hydrogeologic Unit 6 (HU6) was encountered in CPT-03 from approximately 191 feet bsg to <br /> approximately 210 feet bsg. The lateral extent of HU6 is not well defined at the site; CPT-01, <br /> CPT-02 and CPT-04 were terminated prior to encountering HU6. HU6 is composed primarily of <br /> fine-grained soils including clayey silt and silt. HU6 is characterized by generally moderate to high <br /> pore pressures. <br /> ANALYTICAL RESULTS OF GROUND WATER SAMPLES <br /> Various concentrations of target analytes were detected in each grab ground water sample collected <br /> from each sampling interval in soil borings advanced near the former UST No. 3 location(CPT-01 <br /> through CPT-03). Analytes of concern were not detected above laboratory reporting limits in grab <br /> ground water samples collected from soil borings advanced near the former UST cluster area(CPT- <br /> 04 and CHB-01). <br /> Former UST No. 3 Location <br /> Analytical results of CPT ground water sampling at the former UST No. 3 area are as follows: <br /> • HU-2: TPH-g and TPH-d were detected in the ground water sample collected from HU-2 at <br /> a concentration of 27,000 micrograms per liter(µg/1)and 8,800µg/l,respectively,in sample <br /> CPT03/50-54. BTEX constituents were detected in the same sample at concentrations of 21 <br /> µg/l(benzene), 1,000 gg/l(toluene), 1,700µg/l(ethylbenzene)and 6,200µg/1(total xylenes). <br /> • HU-3: TPH-g was detected in ground water samples collected from HU-3 at concentration <br /> ranging from 110 µg/1 to 190 µg/1 in samples CPT03/74-78 and CPTO1/77-81,respectively. <br /> BTEX constituents were detected at concentrations as high as 12 µg/1 benzene <br /> (CPTO1/77-81), 27 µg/1 toluene(CPTO1/77-81), 8.6 µg/1 ethylbenzene(CPT03/74-78) and <br /> 38 9g/1 total xylenes(CPT03/74-78). TPH-d was not detected in the ground water samples <br /> collected from HU-3. <br /> • HU-4: TPH-g and TPH-d were detected in ground water samples collected from HU-4 at <br /> concentrations as high as 30,000 µg/1 and 25,000 µg/1, respectively in sample <br /> CPT02/137-141. BTEX constituents were detected at concentrations as high as 180 gg/l <br /> benzene(CPTO1/93.5-97.5),2,300µg/1 toluene(CPT02/137-141), 1,200 µg/1 ethylbenzene <br /> Advanced GcoEnvironmental,Inc. <br />