Laserfiche WebLink
SAN JOAQUIN COUNTY DATE 2/3/03 <br /> ENVIRONMENTAL HEALTH DEPARTMENT PAGE 1 PR# 2 1 o7733 <br /> of 6 <br /> 304 E. Weber Ave., Third Floor, Stockton, CA 95202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility Name 7-ELEVEN Facility Address 2725 COUNTRY CLUB BLVD, STOCKTON <br /> Facilty Contact MOHAMMAD RIZWAN Title_CASHIER Phone # (209) 463-1259 <br /> UST# 507934 Product UL UST#507935 Product SUL <br /> Overfill Prevention: D Audible/Visual X Mechanical On UL Only--None on SUL Monitoring Panel: VR TLS 35OR <br /> Piping System: D Gravity X Pressure 0 Suction Violations: D Minor X Major <br /> Automatic Pump Shut Down Satisfies CCR 2636 D Yes X No Dispenser Pan: X Yes D No <br /> INSPECTION TYPE: X Routine X Monitoring Certification ❑Complaint []Install []Removal ❑Repair/Upgrade <br /> COMPANY NAME:TANKNOLOGY TECHNICIAN NAME:KEVIN MATLOCK PHONE: 209 365-1246 <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 1�SC 25284 Permit to operate 20 CCR 2712 (b) Maintenance & monitoring <br /> 2 CCR 2637 Secondary cont testing (6 records <br /> month/36 month) 21 CCR 2636 (f)(4) Annual line tightness test <br /> 3 CCR 2711(b) & (c) Current State Forms A& B 22 CCR 2630(d) Annual line leak detector test <br /> 4 HSC 25292.2 Certification of financial 23 CCR 2630 (d) Annual monitoring certification <br /> responsibility and letter from 24 CCR 2643 (d) Daily monitoring of suction <br /> chief financial officer piping that is not continuously <br /> 5 CCR 2630 (d) Continuous monitoring system monitored <br /> for UST system 25 CCR 2636 (a) Conventional suction piping <br /> 6 CCR 2636 (c)(1) All releases in secondary piping shall have continuous <br /> flow to a collection sump monitoring &20 containment <br /> 7 HSC 25291 (e) Water in secondary(20) cont 26 CCR 2643 (e) Biennial tightness test of gravity <br /> 8 HSC 25291 (f) Automatic line leak detector(s) piping that is not continuously <br /> 9 CCR 2636 (f)(1) Continuous monitoring system monitored <br /> for underground piping 27 CCR 2662 Upgrade requirements for UST <br /> 10 CCR 2632 (c)(2) Continuous monitoring system system <br /> for UST 28 CR 2661 Permit to repair UST system <br /> 11 HSC 25291(a)(2) Secondary containment for 29 HSC 25286 (a) Permit to alter monitoring <br /> UST is tight system <br /> 12 CCR 2636 (0(1) Continuous monitoring system 30 HSC 25298 (a) Illegal abandonment of UST <br /> for dispenser system system <br /> 13CR 2635(b)(1) Spill container 31 HSC 25298(b) Permit to temporarily close UST <br /> 14 CCR 2635 (b)(2) Overfill prevention system system <br /> 15 CCR 2631 (a) Primary containment is product- 32 HSC 25298(c) Permit to close UST system <br /> tight 33 HSC 25291 (e) Water in 2°cont analyzed and <br /> 16 HSC 25292.1 UST system is operated to properly disposed of <br /> prevent unauthorized release 34 CCR 2640 (e) Single wall component within <br /> 17CR 2650 Recording/reporting 1000' of Public Well, no ELD <br /> unauthorized release 35 CR 2635(a)(2)(A) Cathodic protection testing <br /> 18 CCR 2632 (d) Monitoring &response plan 36 H&SC 25299(a)(9)Disabling leak detect. devices <br /> 19 CCR 2712(i) Monitoring & response plan is 37__V Violation(s) not listed above <br /> on site <br /> EHD INSPECTOR:KASEY FOLEY, REHS PHONE: (209)468-3451 <br /> RECEIVED BY: MAILED 2/6/03 TITLE: <br /> UNITIIIlUSTIINSP(rev]126102) <br />