Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
725
>
1600 - Food Program
>
PR0516571
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/8/2021 4:42:14 PM
Creation date
6/10/2019 3:52:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0516571
PE
1625
FACILITY_ID
FA0012682
FACILITY_NAME
Wendy's #656 W. Hammer Lane
STREET_NUMBER
725
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
725 W Hammer Ln
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Time In: 10.59 am <br /> Time Out: 11:57 am <br /> PquitY San Joaquin County <br /> )O. .QOG <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> • cq.. �a• Telephone: (209)468-3420 Fax:(209)464-0138 Web:www.sigov.org/ehd <br /> �/PORN <br /> Food Program Official Inspection Report <br /> Name of Facility: Wendy's Date: 03/24/2017 <br /> Address: 725 W Hammer Ln, STOCKTON 95210 <br /> Owner/Operator: DESMOND FOODS LP Telephone: (559)435-9648 <br /> Program Element: 1625-RESTAURANT/BAR 51-100 SEATS <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit Reinspection on or after: 04/07/2017 <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7; <br /> 113700.All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and have the potential to cause foodborne illness.All major violations must be corrected immediately.Non-compliance may warrant immediate closure of <br /> the food facility. <br /> #14 Food Contact Surfaces Sanitized or Warewashing Sanitization MAJOR <br /> OBSERVATIONS:No sanitizer in the 3 comp sink. Corrected on site now at 200ppm (quat). <br /> No sanitizer in sanitizer bucket. Ok, corrected on site now at 200ppm (quat). <br /> CALCODE DESCRIPTION:All food contact surfaces of utensils and equipment shall be clean and sanitized. (I 13984(e), 114097, <br /> 114099.1, 114099.4, 114099.6, 114101 (b-d), 114105, 114109, 114111, 114113, 114115(a, b, d), 114117, 114125(b), 114135, 114141) <br /> #6 Handwashing Facilities Supplied and Accessible <br /> OBSERVATIONS:Hand sink temperatures in kitchen are below 100F. Provide at 100F or higher. <br /> One hand sink is at 118F (next to 3 comp)and is not on a readily adjustable faucet. <br /> Provide at 100F-108F. <br /> Observed a trash can, boxes, and food rack in front of hand sink. Remove. Hand sink to be unobstructed. <br /> Observed container in hand sink. Remove. Corrected onsite. <br /> Paper towels are lacking at hand sink at drive thru. Provide. <br /> CALCODE DESCRIPTION:Handwashing soap and towels or drying device shall be provided in dispensers dispensers shall be <br /> maintained in good repair. (113953.2) Adequate facilities shall be provided for hand washing,food preparation and the washing of <br /> utensils and equipment. (113953, 113953.1, 114067(0) <br /> #39 Thermometers Provided/Accurate/Easily Visible <br /> OBSERVATIONS:Thermometers are lacking for a few units. Provide. <br /> CALCODE DESCRIPTION:An accurate easily readable metal probe thermometer suitable for measuring temperature of food shall be <br /> available to the food handler. A thermometer+/-2#F shall be provided for each hot and cold holding unit of potentially hazardous foods <br /> and high temperature warewashing machines. (114157, 114159) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:Mop sink is leaking at faucet head. Repair/replace. <br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances,shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> FA0012682 PRO516571 SCO01 03/24/2017 <br /> EHD 16-23 Rev.06/30/15 Page 1 of 2 Food Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.