' Site Background Information West Clay Properties <br /> Page 5 of 6 <br /> Hydrogeologic Unit 5 (HU5) extends from a minimum depth of 166 feet bsg to approximately 191 <br />' feet bsg, HU5 is composed primarily of coarse-grained soils including sand and gravelly sand <br /> interbedded with minor silt and clayey silt and silt HU5 is characterized by generally low pore <br /> pressures, and may be classified as a flow unit HU5 was observed in borings CPT-03 and CPT-04 <br />' and appears to be laterally continuous beneath the site <br /> Hydrogeologic Unit 6 (HU6) was encountered in CPT-03 from approximately 191 feet bsg to <br />' approximately 210 feet bsg The lateral extent of HU6 is not well defined at the site, CPT-01, <br /> CPT-02 and CPT-04 were terminated prior to encountering HU6 HU6 is composed primarily of <br /> fine-grained soils including clayey silt and silt HU6 is characterized by generally moderate to high <br />' pore pressures <br />' ANALYTICAL RESULTS OF GROUND WATER SAMPLES <br /> Various concentrations of target analytes were detected in each grab ground water sample collected <br /> from each sampling interval in soil borings advanced near the former UST No 3 location(CPT-01 <br /> through CPT-03) Analytes of concern were not detected above laboratory reporting limits in grab <br /> ground water samples collected from soil borings advanced near the former UST cluster area(CPT- <br /> 04 and CHB-01) <br />' Former UST No 3 Location <br /> Analytical results of CPT ground water sampling at the former UST No 3 area are as follows <br />' • HU-2 TPH-g and TPH-d were detected in the ground water sample collected from HU-2 at <br /> a concentration of 27,000 micrograms per liter(µg/1)and 8,800µg/1,respectively,in sample <br />' CPT03/50-54 BTEX constituents were detected in the same sample at concentrations of 21 <br /> µg/1 (benzene), 1,000 µg11 (toluene), 1,700 µg11 (ethylbenzene) and 6,200 µg/l (total <br /> xylenes) <br />' HU-3 TPH-g was detected in ground water samples collected from HU-3 at concentration <br /> ranging from 110 µg/l to 190µg/l in samples CPT03/74-78 and CPT01/77-81,respectively <br /> BTEX constituents were detected at concentrations as high as 12 µg/l benzene <br /> (CPTO1/77-81), 27 µg/l toluene (CPT01/77-81), 8 6 µg/l ethylbenzene(CPT03/74-78) and <br /> 38 µg/l total xylenes (CPT03/74-78) TPH-d was not detected in the ground water samples <br />' collected from HU-3 <br /> • HU-4 TPH-g and TPH-d were detected in ground water samples collected from HU-4 at <br /> concentrations as high as 30,000 µg/1 and 25,000 µg/l, respectively in sample <br /> CPT02/137-141 BTEX constituents were detected at concentrations as high as 180 µg/l <br /> benzene(CPT01/93 5-97 5),2,300 µg11 toluene(CPT02/137-141), 1,200µg/1 ethylbenzene <br /> • (CPT02/137-141) and 6,600 µg/l total xylenes (CPT02/137-141) <br /> Advanced GeoEnvironmental,inc <br /> 1 <br />