My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
14700
>
2800 - Aboveground Petroleum Storage Program
>
PR0516327
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2019 11:37:41 AM
Creation date
6/17/2019 3:51:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0516327
PE
2832
FACILITY_ID
FA0006674
FACILITY_NAME
OWENS-BROCKWAY GLASS CONTAINER INC
STREET_NUMBER
14700
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
209-240-24
CURRENT_STATUS
01
SITE_LOCATION
14700 W SCHULTE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
01: Bill Boscacci <br /> GAEnvironmentalSpecialist <br /> 14700 W Schulte Road <br /> July 8, 2019 Tracy,CA 95377 <br /> Tel:567-336-8269 <br /> l�, E <br /> San Joaquin County Environmental Health Department <br /> Attn: Lydia Baker, EHD <br /> 1868 East Hazelton Avenue <br /> Stockton, CA 95205-6232 <br /> Re: Owens-Brockway Glass Container Inc. Tracy Plant ("Owens") <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Dear Ms. Lydia Baker <br /> This letter was written in response to the alleged open violations from the Health <br /> Department's Aboveground Petroleum Storage Act Inspection Report, dated June 05, 2019, <br /> and received by Owens via email on June 05, 2019. The responses will be referencing the <br /> updated SPCC Plan which is pending Professional Engineer (PE) certification, as some of the <br /> structural containment is being put in place. The SPCC Plan will be certified upon <br /> completion of the secondary containments and submitted by July 31tn <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Violation# 105—CFR 112.1(b)(3), 112.2 Failure to properly close tanks when making a claim of permanently <br /> closed. <br /> The out of service diesel tank inside the fire pump building D is not in use but has not been properly closed.When a <br /> tank is not in use, it must be permanently closed by meeting the following conditions: <br /> -remove all liquid and sludge from each container and connecting line <br /> -disconnect and blank off all connecting lines and piping have from the tank <br /> -close and lock all valves <br /> -post a sign conspicuously stating that it is a permanently closed container and denoting the date of closure. <br /> Immediately"Permanently Close"all tanks that are not being used or ensure that the SPCC plan is amended to <br /> include all petroleum tanks that have not been permanently closed. <br /> This is a Class II violation. <br /> Response: <br /> Owens has labeled the out of service diesel tank inside the fire pump building D, "Permanently <br /> Closed, June 26, 2019". Photo attached (Figure 1). <br /> Violation#301—CFR 112.5(a) Failed to amend Plan as necessary. <br />
The URL can be used to link to this page
Your browser does not support the video tag.