Laserfiche WebLink
EXPLANATION OF TERMS <br /> BLANK QA/QC - Analyte free sample analyzed to determine if background contamination is present in any instrument or techniques used for analysis. <br /> TYPES <br /> DLR => Detection Limit for Reporting purposes. <br /> MDL => Method Detection Limit. This number represents the smallest non-zero value that FGL can reproduce for a method. The DLR must <br /> be greater than or equal to the MDL. <br /> CALIBRATION QA/QC - Standard analyzed to determine the Accuracy of any instruments and/or techniques used for analysis. <br /> 1YPES <br /> ICY => independent Calibration Verification standard. Analyzed to check the accuracy of the standard used to calibrate an instrument or technique. <br /> CCV => Continuing Calibration Verification standard. Analyzed to check the accuracy of the instrument or technique calibration. <br /> LCS => Laboratory Control Standard. Analyzed to check the accuracy of the entire method from prep thru analysis. <br /> OLS => Detection Level Standard. Used for verification and determination of MDL. <br /> METHOD QA/QC - Matrix specific samples analyzed to determine accuracy and/or precision of the entire method. <br /> TP <br /> Dup => Samples are prepared and analyzed in Duplicate to determine the Precision of the method. The RPD or Relative Percent Difference is calculated and <br /> compared to the MAY for all constituents. <br /> BS => Blank Spike / Blank Spike Duplicate. R Laboratory Blank matrix is Spiked with a known amount of analyte then prepared and analyzed along with a <br /> batch of samples. <br /> MS => Matrix Spike / Matrix Spike Duplicate. A Client provided matrix is Spiked with a known amount of analyte then prepared and analyzed along with a <br /> batch of samples. <br /> CALCULATIONS <br /> l % REC => Percent Recovery of an analyte introduced (spiked) at a know level (Concentration). % REC should be within the AR. <br /> J AR => Acceptance range of the % REC for an analyte. The AR is determined by averaging all % REC data for a specific matrix and then calculating the <br /> 95 % confidence interval. <br /> % DIF => (Relative) Percent Difference of a sample analyzed in duplicate. % DIF should be <= MAY. <br /> MAY => Maximum Acceptance Value for the % DIF of an analyte. The MAY is determined by averaging all % DIF data for a specific matrix and then calculating <br /> the 95 % confidence Interval. <br /> Conc. _> The theoretical ammount of analyte present in the sample prior to analysis. <br /> ♦ _> Indicates a special or modified DLR was applied for the acceptance criteria. <br /> _> Indicates the average concentration spiked for MS/MSD or BS/BSD when the concentration spiked was not identical for both QC samples. <br />