My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
32727
>
2900 - Site Mitigation Program
>
PR0517291
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2019 9:56:38 AM
Creation date
6/19/2019 9:50:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0517291
PE
2959
FACILITY_ID
FA0013309
FACILITY_NAME
TRACY TEST FACILITY
STREET_NUMBER
32727
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25112004
CURRENT_STATUS
01
SITE_LOCATION
32727 CORRAL HOLLOW RD
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' GENERAL DYNAMICS <br /> Additional Investigation— Ro 3 SWMU21 Workplan Revised Novenn003 <br /> ' 4.0 Sample Containers, Preservation, and Documentation <br /> ' Soil will be collected in 6-inch by 2-inch brass sample sleeves (hollow stem). After <br /> removal from the sample barrel the ends of the soil sample containers will be covered <br /> with Teflon® plastic sheeting and sealed with slip-on plastic end caps. Groundwater <br /> ' samples will be collected in unpreserved 1-liter amber glass bottles equipped with <br /> screw-on caps. Samples of soil and groundwater collected during the performance of <br /> the scope of work will be properly preserved and documented. <br /> ' After collection of the sample a label containing the following information will be <br /> attached to the sample container; 1) date and time of collection, 2) sample identification <br /> ' number, 3) project number, 4) identity of sample collector, and 5) analysis required. <br /> Sample collection information will be entered onto a Chain of Custody (COC) form that <br /> will accompany the samples during their residency at the site and during transport to the <br /> laboratory that will perform the requisite analysis. <br /> Preservation of the sample(s) will be achieved by placing the sample containers into a <br /> pre-cooled container and maintained at a temperature of approximately 4 °C until the <br /> sample(s) are delivered to the laboratory. Preservation of the sample(s) beyond cooling <br /> is not required. <br /> ' Copies of the COC will be included with the analytical results presented in the report <br /> that will be prepared to document this investigation and remediation. <br /> 5.0 Analytical Protocol and Quality Assurance and Quality Control (QA/QC) <br /> Soil and groundwater samples will be submitted to a laboratory certified by the DTSC <br /> for analysis of the following constituents, <br /> • TPHd using United States Environmental Protection Agency (USEPA) Modified <br /> Method 8015, and <br /> SVOCs using EPA Method 8270c <br /> Samples will be analyzed within the required holding times for the specific analyses. <br /> Attached in Appendix A is a letter from the analytical laboratory, McCampbell Analytical <br /> of Pacheco, CA that states that they have compared the chromatograms from the TPHd <br /> ' analyses from soil samples at S-26 and the groundwater samples from S-33 with <br /> standard petroleum hydrocarbons chromatograms. The laboratory indicated that the <br /> petroleum hydrocarbon detected from the site samples most closely resemble mineral <br /> ' oil. <br /> Laboratory QA/QC will be performed in accord with the requirements for the analysis of <br /> TPHd and SVOCs as specified in the current USEPA SW-846. Field QA/QC will consist <br /> of the inclusion of a trip blank for evaluation of sample cross-contamination during <br /> ' transport of the sample(s). The trip blank will only be included and analyzed for TPHd <br /> CHOW ENGINEERING, INC. 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.