Laserfiche WebLink
i <br /> h <br /> TABLE 1 '! <br /> i. <br /> LABORATORY RESULTS !' <br /> FLAME IONIZATION DETECTOR ANALYSIS <br /> CONCENTRATIONS IN MICROGRAMS-PER-LITER <br /> PENTANE/ ETHYL- m- & p 0- TOTAL <br /> SAMPLE MTBE BENZENE TOLUENE BENZENE XYLENE 11XYLENE VOLATILES' <br /> i <br /> 4 <1. 0 <1. 0 <1.0 <1.0 <1. 0 <1.0 172 <br /> 5 <1. 0 <1. 0 <1.0 <1. 0 <1.0 ! <1.0 17 <br /> 6 1,886 9. 3 830 70 26 ! 23 16, 650 <br /> 7 2,902 19 1,710 68 10 21 19, 660 <br /> _ 8 ., <1. 0 <1.0 1. 3 <1.0 <1. 0 «i <1. 0 16 <br /> 9 <1. 0 <1.0 <1. 0 <1. 0 <1.0 <1. 0 <1. 0 <br /> 10 3.9 <1. 0 <1.0 <1. 0 <1.0 <1. 0 36 <br /> 11 1. 1 <1. 0 2.0 <1.0 <1. 0 <1.0 23 <br /> 13 2.7 <1.0 2.2 <1.0 <1. 0 ;�� <1. 0 23 <br /> 14 19,760 2,051 1,932 946 216 52 97, 110 <br /> 15 9 .8 <1_0 2.9 3.2 1.2 j <1. 0 129 <br /> 16 <1.0 <1.0 <1.0 <1.0 <1. 0 <1_0 2. 1 <br /> 17 <1.0 <1.0 <1.0 <1.0 <1. 0 <1.0 1. 3 <br /> 18 <1.0 <1.0 <1.0 <1_0 <1.0 �! <1.0 <1. 0 <br /> 19 <1. 0 <1.0 <1.0 <1.0 <1.0 ii <1.0 <1.0 <br /> 20 <1.0 <1. 0 <1.0 <1.0 <1.0 <1. 0 <1.0 <br /> 21 <1.0 <1.0 <1.0 <1.0 <1.0 ii <1.0 <1.0 <br /> 22 : <1.0 <1.0 <1.0 <1.0 <1.0 <1. 0 <1.0 <br /> 23 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 19 <br /> 24 <1.0 <1.0 <1.0 <1_0 <1.0 <1.0 <1.0 <br /> 25 <1.0 <1.0 <1.0 <1.0 <1.0 ! <1_0 <1.0 <br /> 26 <1.0 <1.0 <1.0 <1.0 <1.0 ! <1.0 <1.0 <br /> 27 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <br /> 28 <1.0 <1.0 <1.0 <1.0 <1. 0 <1..0 <1.0 <br /> u <br /> i <br /> I <br /> 'i <br /> r i <br /> it <br /> i <br /> CONCENTRATIONS BASED ON RESPONSE FACTOR OF MTBE <br /> 2CALCULATED USING THE SUM OF THE AREAS OF ALL INTEGRATED CHROMATOGRAM <br /> ii <br /> PEAKS,,; AND THE INSTRUMENT RESPONSE FACTOR FOR TOLUENE <br /> it <br /> I <br /> ii <br /> ii <br /> 'I <br /> - ii I <br />