Laserfiche WebLink
Interim Remedial Action Test Report,Former Unocal#0187,Stockton,CA <br /> August is,2001 <br /> T" <br /> PH <br /> most significant wells for evaluating the effectiveness of the system are wells NP-1-65 and <br /> NP-1-111 These are near the sparge points and screened at approximately the same depths In well <br /> NP-1-65, the TPHg concentrations decreased from 33,000 ppb at the test baseline to less than 2,000 ppb <br /> on July 17, 2001 This is a decrease of at least 94% There was a dramatic decrease, to 773 ppb, <br /> approximately one month after beginning the test Since that time levels have fluctuated between 60 6 <br /> and 2800 ppb In well NP-1-111, TPHg concentrations went from 170 ppb at the test baseline to less than <br /> 50 0 ppb on January 9, 2001, and has remained below detection limits since that time <br /> The screen interval of well NP-1-22 begins approximately 40 feet above the level of the sparge points <br /> The TPHg concentrations reported at the baseline was 12,000 ppb The concentrations reported on July <br /> 17, 2001 was 5,700 ppb Although not as dramatic as the decreases in wells NP-1-65 and NP-1-111,this <br /> is still a decrease of 53% from the baseline concentrations, and represents a very significant downward <br /> trend in TPHg concentrations It is particularly evident when compared to the historical quarterly <br /> monitoring data in Appendix E <br /> Analysis of sample results from well NP-2 does not point to any significant conclusions There appears <br /> to be general downward trend in TPHg concentrations,but there are no major decreases <br /> On-site monitoring well U-3 is within the treatment area The well is screened from 30 to 55 feet bgs <br /> On November 20, 2000, the last quarterly sampling event before the test, TPHg concentrations were <br /> reported to be 12,300 ppb This was consistent with previous results for this well For the May 14, 2001 <br /> sampling event, after approximately five months of system operation, the well was non-detect for TPHg <br /> This is a decrease of over 99% <br /> On-site monitoring wells U-1 and U-2 are upgradient of the treatment area On November 20, 2000, <br /> TPHg were non-detect in both wells For the May 14, 2001 sampling event, TPHg concentrations had <br /> increased in wells U-1 and U-2 to 1380 and 376 ppb, respectively This result was not expected <br /> Benzene <br /> At the test baseline, benzene concentrations in wells NP-1-22, NP-1-65 and NP-1-111 were 740, 2,000, <br /> and 4 8 ppb, respectively On July 17, 2001, benzene concentrations in wells NP-1-22 and NP-1-65 were <br /> reported to be 240 and 88 ppb, respectively, and benzene was non-detect in well NP-1-111, which are <br /> decreases of 68%,96%, and over 90% respectively <br /> A review of sample results from well NP-2 does not show any specific,consistent concentration changes <br /> For well U-3, the benzene concentration was reported at 515 ppb on November 20, 2000 For the May <br /> 14, 2001 sampling event,benzene was non-detect in well U-3 This is a decrease of over 99% <br /> Monitoring wells U-1 and U-2 showed increases in benzene concentrations similar to the increases in <br /> TPHg concentrations On November 20, 2000 benzene levels in both wells were reported to be less than <br /> the detection limit of 0 500 ppb For the May 14, 2001 sampling event the benzene levels had increased <br /> to to 19 1 ppb and 14 4 ppb respectively <br /> 24004209-1 8 <br />