REVISED PUMP TEST PLAN <br /> The presence of the two groundwater zones, A and B and the presence of the monitor "ells MW1 <br /> through MW5 which are screened across both zones, complicates the performance of a pump test at <br /> this site <br /> Of major concern is the location of MWI in relation to RWl A and RW I B and the MW6 cluster <br /> With monitor wells completed across both zones pumping from one zone will cause flow up or <br /> down the cross zone well from the non-pumped zone <br /> Because the modeling was only preliminary a simple analog model of the interaction of pumping <br /> from RWOIA and the cross-zonal flow in MWI was developed The flow up the well is driven by <br /> the difference in head between the two groundwater zones Even in two inch casing, the anticipated <br /> flow between the two zones is significant with even a slight difference in head <br /> From the Hazen-Williams Formula, for anticipated flow in a pipe <br /> Q=0 432C1D2 635054 <br /> Q= ft3/s <br /> C1= Coefficient dependent on surface roughness approximately 120 <br /> D= pipe diameter in feet <br /> S =head lose in feet per feet of pipe <br /> For a 2-inch pipe with a differential of 0 01 feet per the 3-foot clay layer that separates the zones <br /> the flow in the pipe would be 13830 gallons per day <br /> D=2/12=0 167 <br /> S=0 113=0 033 <br /> Q=0 432*120*0 1672 63*0 00330 54=0 0214 ft3/sec =1 284 cfm = 9 604 gpm or 13830 gpd <br /> From the above it can be assumed that flow between zones in MWI would be sufficient to equalize <br /> the head between the two zone even in response to significant pumping at RWOI <br /> The preliminary model used the distance drawdown equation to calculate the response to pumping <br /> The equation was solved for three instances <br /> I The response of the upper zone from pumping RW01 A <br /> 2 The response of the upper zone to the flow of water from the lower zone to upper zone at <br /> MWI <br /> •3 The drawdown of the lower zone in response to flow from the lower zone to the upper zone in <br /> MW1 <br /> While running the model the flow parameter in MWI between the two zones was adjusted so that <br /> the groundwater elevation for both the A and B zone were equal, as the zones responded to <br /> pumping at RW 1 A <br /> In an analog model the resulting drawdowns are considered to be additive The model indicated <br /> that the flow at MWI would be great enough to significantly affect the response of the upper <br /> 1 <br /> Rev Pump Test Pian- 10/11/02 <br />