My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0006117
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1876
>
2900 - Site Mitigation Program
>
PR0542421
>
ARCHIVED REPORTS XR0006117
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/21/2019 1:21:41 PM
Creation date
6/21/2019 10:45:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006117
RECORD_ID
PR0542421
PE
2950
FACILITY_ID
FA0024377
FACILITY_NAME
COUNTRY CLUB BLVD/295950
STREET_NUMBER
1876
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12319101
CURRENT_STATUS
01
SITE_LOCATION
1876 COUNTRY CLUB BLVD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
265
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f-1EALTH AND SAKTATi'ON CODE <br /> D- Each business establishment for which a frequency of sampling, point of discharge,volumetric <br /> . grease interceptor is required shall have an or seasonal restrictions, or other discharge <br /> interceptor, which shall serve onty that business conditions and limitations will be as specified in the <br /> establishment. Discharge Permit which shall be issued by the <br /> E. Buildings remodeled for use requiring Director of Municipal Utilities. <br /> interceptors shall be subject to these regulations. 2. Discharges shall not exceed a concentration <br /> F. Waste discharge from fixtures and of 4.57 mg/l of Total Toxic Organics (as currently <br /> equipment in the above-mentioned types of listed by the Environmental Protection Agency for <br /> establishments which may contain grease or other categorical electroplating dischargers, 40 CFR <br /> objectionable materials, including, but not limited to, 413.02 ()). Compliance with this provision will be <br /> scullery sinks, pot and pan sinks, dishwashers, food enforced by grab samples obtained no less than <br /> waste disposals, soup kettles, etc. and floor drains once during the permit term. Analytical procedures <br /> located in areas where such objectionable materials will be in accordance with EPA rules in Guidelines <br /> may exist, may be drained into the sanitary waste Establishing Test Procedures for the Analysis of <br /> through the interceptor when approved by the Pollutants: Final Rule (40 CFR Part 136) Methods <br /> Director. Exception:toilets,urinals, and other fixtures 624 and 625_ In addition, analysis by the permittee <br /> containing fecal material may not flow through the for benzene, toluene, xylene and ethylbenzene <br /> interceptor. (BTXE)will be required at frequencies coinciding with <br /> G. The interceptors shall be maintained in the sampling and analysis for total petroleum <br /> efficient operating condition by periodic removal of hydrocarbons. <br /> the accumulated grease. No such collected grease 3. The discharger shall provide a recording <br /> shall be introduced into any drainage piping or public Lower Explosive Limit(LEL) monitor. Installation will <br /> or private sewer. be at a location in the discharge system prior to entry <br /> H. Abandoned grease interceptors shall be into the sanitary sewer. The monitor is to be <br /> emptied and filled as required for abandoned septic calibrated in a manner that indicates the percentage <br /> tanks in Section 1119 of the Uniform Plumbing Code. of LEL of gasoline and shall be connected to the <br /> I. The cover for grease interceptors shall be facility in such a way that an alarm wrill be triggered at <br /> one-half inch (127 steel plate reinforced as required ten percent (10%) of the LEL of gasoline and the <br /> by the Director,said reinforcing to depend upon the entire facility twill be automatically shut dovam. The <br /> load to be imposed on the plate. Except as monitor shall be calibrated and maintained with a <br /> otherwise provided,the cover shall be gas-tight on all quality assurance program satisfactory to the <br /> interceptors and the waste shall enter the interceptor Director of Municipal Utilities. If, after a period of <br /> through the inlet pipe only. evaluation, it is determined by the Director or a <br /> J. Interceptors shall be installed in such a designated representative that continuous recording <br /> manner that drainage from area outside the area is no longer needed, the provision of a recorder may <br /> intended to be served may not enter, be deleted,.-- <br /> (Added <br /> eleted -(Added by Ordinance 3712C.S.—Effective Jan. 5, 4. The Director or a designated representative <br /> 1984) shall have access to the facility shutdown switch as <br /> well as copies of keys to all locked enclosures at the <br /> SEC.7-089.20. DISCHARGE OF PETROLEUM site and shall be provided access to the facility for <br /> CONTAMINATED purposes of inspection. <br /> GROUNDWATER: 5. The discharger shall provide flow monitoring <br /> It shall be unlawful for any person to discharge and recording equipment and sampling taps or <br /> petroleum contaminated groundwater to the sanitary equipment in order to comply with these rules. <br /> sewer collection system of the City of Stockton, 6. The discharger shall insure that all <br /> except as provided for hereunder, and in accordance pretreatment facilities including, but not limited to, <br /> with the following conditions and restrictions: flow measuring and LEL monitors, are maintained in <br /> 1. The maximum allowable concentration of proper working order at all times. All measuring <br /> total petroleum hydrocarbons in the discharge devices are to be calibrated for accuracy at a <br /> entering the sanitary sewer shall be 100 mg/l. frequency as prescribed by the manufacturer of the <br /> Compliance with this provision will be enforced by monitoring device by a qualified technician approved <br /> periodic self monitoring and laboratory analysis by by the Director. <br /> the discharger fortotal petroleum hydrocarbons over 7. In the event a required flow measuring <br /> the course of the discharge. Sample collection, device is found to be inoperative or to provide <br /> 7-35 <br />
The URL can be used to link to this page
Your browser does not support the video tag.