My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE FILE 3
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2103
>
3500 - Local Oversight Program
>
PR0544591
>
SITE INFORMATION AND CORRESPONDENCE FILE 3
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/21/2019 3:12:00 PM
Creation date
6/21/2019 11:55:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
FileName_PostFix
FILE 3
RECORD_ID
PR0544591
PE
3526
FACILITY_ID
FA0005220
FACILITY_NAME
CHEVRON #9-4054
STREET_NUMBER
2103
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12308029
CURRENT_STATUS
02
SITE_LOCATION
2103 COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ARCADIS BBL Mr. Michael J . Infurna <br /> April 5, 2007 <br /> Amended Task 2 — Vapor Intrusion Pathway Evaluation <br /> The vapor inhalation pathway will be evaluated by collection and analysis of nine soil <br /> gas samples from nine permanent sampling locations within 40-feet by 40-feet grid <br /> cells as identified on Figure 1 . Nine soil vapor samples will be collected from <br /> approximately 1 foot above the water table. Vapor probe installation and sampling <br /> will be performed in accordance with Chevron 's Soil Vapor Sampling Technical <br /> Toolkit (Version 1 .6) and DTSC guidelines. <br /> ARCADIS BBL has selected the direct-push soil vapor sampling probe (implant type) <br /> as detailed in Section II , Subsection B of Chevron's Soil Vapor Sampling Technical <br /> Toolkit for the proposed nine vapor probes. <br /> Deep Vapor Probes Installation <br /> To install the deep probes, a direct-push rig will be used to advance a series of drive <br /> rods to within 1 foot of the water table (approximately 7 feet bgs) in each of the nine <br /> proposed locations. A round of water-level measurements will be collected from the <br /> on-site water-table monitoring wells to determine the actual depth-to-water <br /> immediately prior to initiating the drilling activities. When the targeted depth is <br /> reached , the probe will be slid down the bore of the drive rods. As the drive rods are <br /> removed, a sand pack will be placed around the probe (extending from <br /> approximately 7-6 feet bgs) followed by a dry granular bentonite seal (extending from <br /> approximately 6-5 feet bgs), hydrated granular bentonite (extending from 5-1 feet <br /> bgs), and a 1 -foot cement cap. The soil vapor tube will be fitted with a gas-tight cap <br /> (such as Swagelok ® cap) to eliminate the potential for barometric pressure <br /> fluctuations to induce vapor transport between the subsurface and the atmosphere. <br /> An 8-inch wail box will be installed at surface grade to protect the soil vapor probe. <br /> Vapor Probe Sampling and Analysis Procedure <br /> The soil gas sampling system will be set-up according the DTSC guidelines. To <br /> ensure stagnant or ambient air is removed from the sampling system , a low-flow <br /> pump will be utilized to purge approximately three volumes of dead soil gas at a flow <br /> rate of >200 milliliters per minute (mL/min) . The purge volume of dead space volume <br /> will be calculated based on the internal volume of the tubing and annular space <br /> surrounding the probe tip. A leak test will be conducted to ensure the integrity of the <br /> sampling system . A tracer check compound (e.g . , Freon or helium) will be placed at <br /> locations where ambient air can enter the sampling system . The soil gas samples will <br /> Page: <br /> PmnxnsenrznMmdm.mroCAP Rommex 2/4 <br />