Bulk Storage Container Inspection Fact Sheet July 2012 <br /> Facility owners with AFVO containers that meet the following criteria can conduct visual inspections of <br /> their containers when the following criteria are met: <br /> • Are subject to the Food and Drug <br /> Administration (FDA) regulations in §§112.12(c)(6)(11) <br /> 21 CFR part 110, Current Good For bulk storage containers that are subject to 21 <br /> Manufacturing Practice in CFR part 110, are elevated, constructed of austenitic <br /> Manufacturing, Packing or Holding stainless steel, have no external insulation,and are <br /> Human Food; shop-fabricated, conduct formal visual inspection on <br /> a regular schedule. In addition, you must frequently <br /> • Are elevated; inspect the outside of the container for signs of <br /> • Are made from austenitic stainless deterioration,discharges,or accumulation of oil <br /> steel; inside diked areas.You must determine and <br /> • Have no external insulation; and document in the Plan the appropriate qualifications <br /> • Are shop-built. for personnel performing tests and inspections. <br /> Records of inspections and tests kept under usual <br /> The owner or operator is required to document and customary business practices satisfy the <br /> the procedures for inspections and testing in recordkeeping requirements of this paragraph (c)(6). <br /> their SPCC Plan, including those for AFVO <br /> bulk storage containers that are eligible for Note:The above text is an excerpt of the SPCC rule.Refer to the <br /> full text of 40 CFR part 112. <br /> these differentiated requirements. <br /> In addition, when an AFVO bulk storage container falls outside the scope of an industry standard then <br /> the owner or operator may develop a site-specific inspection and testing program for the equipment that <br /> is in accordance with good engineering practice and documented in the Plan. A PE does not need to <br /> provide and certify an environmental equivalence justification for implementing a hybrid inspection <br /> program when industry standards do not apply to a container or the container is outside the scope of <br /> the standard. However,the hybrid inspection program must be in accordance with good engineering <br /> practice. <br /> What are the requirements to test completely buried tanks? <br /> You must regularly leak test completely buried <br /> metallic storage tanks installed on or after §§712.6(c)(4), 112.12(c)(4) <br /> January 10, 1974. "Regular testing" means Protect any completely buried metallic storage tank <br /> testing in accordance with industry standards or installed on or after January 10, 1974 from corrosion <br /> at a frequency sufficient to prevent leaks. to coatings d cathodic protection compatible with <br /> Appropriate methods of testing should be local soil conditions.You must regularly leak test <br /> 9 such completely buried metallic storage tanks. <br /> selected based on good engineering practice <br /> and tests conducted in accordance with 40 Note:Theabovetextisan excerptofihe SPCCrule.Refertothe <br /> CFR part 280 or a State program approved full text of 40 CFR pal 112. <br /> under 40 CFR part 281 are acceptable. <br /> Describe the method and schedule for testing your completely buried tanks in the SPCC Plan. For more <br /> information on preventing and detecting underground storage tank system leaks see <br /> http/ieoa covioust/prevleak htm. <br /> What are the requirements to inspect bulk §112.9(c)(3) <br /> storage containers at an onshore oil ...periodically and upon a regular schedule visually <br /> production facility? inspect each container of oil for deterioration and <br /> maintenance needs, including the foundation and <br /> You must periodically and upon a regular support of each container that is on or above the <br /> schedule visually inspect each bulk storage surface of the ground. <br /> container(e.g. oil stock tanks, flow-through <br /> process vessels, and produced water Note:The above text isen exceiptofthe SPCC rule.Referto the <br /> containers)for deterioration and maintenance tali text of 40 CFR pan 112, <br /> needs in accordance with §112.9(c)(3), <br /> Astock tank is storage tank for oil production after the oil has been treated(Schlumberger Oil Field Glossary <br /> lurefowwa lossarvo'Ifeldslbcom/default.cfm7 <br /> Office of Emergency Management 8 <br />