COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2700
>
2800 - Aboveground Petroleum Storage Program
>
PR0527774
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2019 9:07:24 AM
Creation date
6/21/2019 1:16:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0527774
PE
2834
FACILITY_ID
FA0007644
FACILITY_NAME
BET STOCKTON TERMINAL
STREET_NUMBER
2700
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14503009
CURRENT_STATUS
01
SITE_LOCATION
2700 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Buckeye Partners L P Tank Inspection Interval Guidelines—Steel Tank Institute(STI)Tanks <br /> As per SPD01,5"Ed.,which was issued September 2011 <br /> • Applies to non-Dregulated tanks with a rated capacity of less than 50.000 gallons[1,190 barrels]and/or having <br /> an STI or UL nameplate. <br /> c Does not apply to tanks having an API 650(or precursor API 12C) nameplate or any tanks largerthan 50,000 <br /> gallons. Such tanks will have inspection intervals in accordance with API 653 guidelines. <br /> • Applies only to certain Aboveground Storage Tanks(ASTs)operating at atmospheric pressure. <br /> o Does not apply to'pressure'vessels operating at greater than 1 psig(e.g.,pressurized propane or butane <br /> bullets). Such tanks will have inspection intervals in accordance with API 510 guidelines. <br /> Tabular Summary of Inspection Intervals for all states otherthan NY PA R,VA which are shown on oaee 2: <br /> Does tank have <br /> CRDM (i.e., is tank Does Tank have <br /> Tank Capacity on concrete pad Spill Control(i.e., STI AST Category External Internal <br /> (Gallons) or on saddles so full secondary Inspection Inspection <br /> [Barrels] leak could be containment)? Interval(Years) Interval(Years) <br /> seen)? <br /> Yes or No No 3 10 N/A <br /> (0-1,100) <br /> [0-26.1] No Yes 2 N/A N/A <br /> Yes Yes 1 N/A N/A <br /> (1,101-5,000) Yes or No No 3 5 10 <br /> [26.2-119.0] No Yes 2 10 N/A <br /> Yes Yes 1 N/A N/A <br /> Yes or No No 3 5 10 <br /> (5,001-30,000) <br /> [119.1-714.2] No Yes 2 30 20 <br /> Yes Yes 1 20 N/A <br /> (30,001-50,000) ENo <br /> No 3 5 10 <br /> [714.3-1190.5] Yes 2 5 15 <br /> Yes 1 20 N/A <br /> Definitions: <br /> Continuous Release Detection Method(CRDM) Spill Control <br /> • Tank having double wall construction • Tank in an impermeable dike('earthen dike areas' <br /> • Tank with integral drip pan are assumed to be impermeable) <br /> • Tank supported by a concrete pad • Tank with integral steel or concrete containment <br /> • Containment volume>_tank volume <br /> Buckeye Inspection Interval Guideline (STI Tanks)—12/18/2012 Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.