Laserfiche WebLink
I <br /> GA-ROVERS Mr. Michael Infurna <br /> & ASSOCIATES November 26, 2008 <br /> southern portion of the site. The highest levels of gasoline constituents are detected in wells <br /> RW4A, MW-5R and MW-18. These data are as expected since the gasoline release at this site <br /> occurred from the former USTs in the southeastern comer of the site. <br /> Wells MW-2 and MW46 provide delineation in the northern portion of the site as these wells <br /> typically contain only MTBE and at levels which are below the MTBE MCL. Well MW-7 <br /> contains MTBE levels slightly higher than those of MW-2, but MW-7 is located 50 feet northwest <br /> of MW-2 and further away from the former USTs than MW-2. We will continue to monitor the <br /> MTBE concentration in MW-7, but based on groundwater flow direction and the low levels of <br /> MTBE observed in MW-2 it may be that the MTBE in MW-7 does not originate from the Shell <br /> site. <br /> Wells MW-8 and MW-15 provide delineation along the western side of the site. Both of these <br /> wells currently have MTBE levels below the MCL and low levels of other gasoline constituents. <br /> Downgradient (southwest) of theses wells is located MW-9 which typically does not contain any <br /> gasoline constituents. MW-9 has contained low levels of MTBE, but never above the MCL. <br /> MW-9 is located on the southern side of Country Club Boulevard. <br /> Wells MW-10 and MW-11 are also located on the southern side of Country Club Boulevard, <br /> further east than MW-9. These wells also typically do not contain any gasoline constituents <br /> except low levels of MTBE, below the MCL. Wells MW-9, MW-10, and MW-11 provide plume <br /> delineation southwest, south and southeast of the site. In addition wells MW-10 and MW-11 are <br /> located between the site and the offsite domestic wells. These two wells serve as sentry wells for <br /> the site to assure the plume is not migrating toward the domestic wells. An additional sentry well <br /> (MW44) is located approximately 670 feet southeast of the site and is screened in the deep zone, <br /> which is also the same zone the closest domestic well is screened in. As mentioned above, this <br /> well has contained sporadic detections of MTBE below the MCL for MTBE. <br /> Perimeter wells MW-3, MW4, and MW-6 provide plume delineation east, and northeast of the <br /> site. These wells typically do not contain gasoline constituents other than MTBE, and in the last <br /> year at levels near or below the MCL for MTBE. <br /> In summary, the existing well network provides adequate plume delineation for this site and is <br /> particularly protective of the domestic wells located southeast of the subject site. Groundwater <br /> flow direction is typically toward the southwest which means the domestic wells are located <br /> crossgradient from the site. Based on the current and historical data for this site there appears to <br /> be little or not threat to the domestic wells southeast of the subject site. <br /> 240783 10 <br /> - Near <br /> Worldwide Engineering, Environmental, Construction, and IT Services <br />