FIELD DOCUMENTS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2782
>
2900 - Site Mitigation Program
>
PR0516515
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 2:39:39 PM
Creation date
6/24/2019 1:50:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0516515
PE
2950
FACILITY_ID
FA0012652
FACILITY_NAME
SAFEWAY STORE #1769
STREET_NUMBER
2782
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
02
SITE_LOCATION
2782 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Groundwater <br /> Sampling Method: One-inch diameter PVC well casing and screen was inserted <br /> down each borehole as a temporary well to facilitate collection of a <br /> grab groundwater sample. Each temporary well was screened <br /> across the water table. Groundwater samples were collected <br /> through the temporary PVC well using '/.-inch polyethylene tubing <br /> equipped with a ball check-valve. The check-valve end of the <br /> tubing was placed downhole into the water column, where the <br /> tubing was rapidly oscillated by hand in an up and down motion, <br /> thereby displacing water up through the tubing to the surface for <br /> sampling. New PVC casing, well screen and sample tubing were <br /> used at each soil boring location. <br /> Soil Cuttings/ <br /> Decon Water: No soil cuttings or equipment decontamination water requiring <br /> storage were generated. <br /> Field Investigation Summary Table <br /> Boring Total Depth Soil Sample Soil Sample OVM Field Depth to Groundwater <br /> ID (feet) Depth(feet) Analyzed Screening Groundwater Sample <br /> (ppm) feet Anal ed <br /> 5 Archived 9.0 <br /> S13-1 16 10 Archived 6.0 11.5 YES <br /> 15 Archived 2.0 <br /> 5 Archived 5.0 <br /> SB-2 16 10 YES 8.0 10 YES <br /> 15 Archived 10.0 <br /> 5 Archived 0.0 <br /> SB-3 16 10 YES 18.0 12 YES <br /> 15 Archived 25.0 <br /> SB-4 11 5 Archived 5.0 8.5 YES <br /> 9 Archived 18.0 <br /> OVM=organic vapor monitor. <br /> Laboratory Analyses: TPH-gas, TPH-diesel and TPH-motor oil by EPA Method <br /> 8015M with silica gel treatment. <br /> VOCs, including BTEX and MTBE, by EPA Method 8260, <br /> low level detection limits. <br /> P:\PROJECTS\Safeway\284\Stockton-103\1769_Pre-Gas_Rptdoc <br />