1 <br /> ' Table 6- Historic Diesel Thickness Measurements and Product Recovery Data(06/18/99 through 9/30/15) <br /> Depth to Cumulative <br /> [Dole <br /> Recovery Depth to Diesel Diesel <br /> Floating Operations and Maintenance Notes <br /> Nell Groundwater Thickness Removed <br /> Diesel <br /> (gallons) <br /> RW-I 14.10 -78./ 731 (3rd quarter G WM event).Initial measured product recovery tank volume <br /> RW-2 14.87 14.90 0.03 20.9proximately 2.0 gallons.Insufficient Fluid column in RA-2,RW-3,and RW-6 m <br /> L8/26105 <br /> RW-3 14.87 14.89 0.02 22.1erate passive skimmers.Charged out nitrogen tank for active skimmer m RW4, <br /> ' RWA 14.11 15.32 111 97.80ed active skimmer,and set urn time/cycle to 10 mhs/3 times daily.Ending measured <br /> RN-5 13.79 duct recovery tank volume approximately 2.0 gallons.*Cumulative total diesel <br /> RW-6 14.51 14.55 0.04 2.78 removed from RW4 revised down 0.70 gallons. <br /> RW-1 - 14.20 - <br /> RW-2 15.01 15.04 0.03 20.93 Initial product recovery tank volume approximately 2.0 gallons.Recovered <br /> RW-3 14'92 14.98 0.06 22.15 approximately 0.24 gallons ofpmducl from RW4 and RW-6 using bailing recovery <br /> RW4 14.17 15.59 1.42 98.02 method.Reinstalled SoakEZ socks in RW-2 and RW-6.Reinstalled active skimmer to <br /> RW-5 - 13.91 RW4,skimmer was left on.Ending recovery lank volume approximately 2.2 gallons. <br /> RW-6 14.61 14.66 0.05 2.80 <br /> ' RW-1 - 14.37 - <br /> RW-2 15.20 15.23 0.03 20,94 Initial product recovery midi volume approximately 2.2 gallons.Recovered <br /> 9/9/05 RW-3 15.15 15.20 0.05 22,17 approximately 0.55 gallons oflu duct flour RW-2,RW-3,RW-0,and RW-busing <br /> RW4 14.36 15.59 1.23 98.57 bailing recovery method.Reinstalled SoakEZ socks in RW-2 and RW-6.Reinstalled <br /> RW-5 - 14.11 - active skimmer in RW4,skimmer was left oa.Ending recovery tank volume <br /> RW-6 14.81 14.86 0.05 282 approximately 2.8 gallons. <br /> ' RW-1 - 14.45 - <br /> RW-2 15.21 15.29 0.09 20.98 Initial product recovery tank volume approximately 2.g gallons.Recovered <br /> 9/16/05 RW-3 15.21 15.27 0.06 22.20 approximately 0.8 gallons of product from RW-2,RW-3,RW-4,and RW-6 using balm, <br /> RW4 14.40 15.51 1.11 99.18 recovery method.Reinstalled SoakEZ socks in RW-2 and RW-6.Removed active <br /> ' RW-5 - 14.17 - skimmer from Site.Ending recovery lards volume approximately 3.6 gallons. <br /> RW-6 14.86 14.98 0.12 2.89 <br /> RW-1 14.48 <br /> RW-2 15.16 15.30 0.14 21.06 Initial product recovery tank volume approximately 3.6 gallons.Recovered <br /> RW-3 15.12 15.28 0.16 22.29 y K P RW -3,RW-0,and RW-6 using bailing <br /> ' 10/7/OS approximate( d. anon of product from RW- <br /> RW-0 14.76 15.57 1.21 99.88 recovery method.Reinstalled SoakEZ socks in RW-2 and RW-6.Ending recovery tank <br /> RW-5 14.27 volume approximately 4.6 gallons. <br /> RW-6 14.90 15.13 0.23 3.02 <br /> RW-1 - 14.38 <br /> RW-2 15.04 15.31 0.27 21.28 Initial product recovery tank volume approximately 4.6 gallons.Recovered <br /> ' 10/31/05 RW-3 15.05 15.11 0.06 22.34 approximately 1.6 gallons ofproduct from RW-2,RW-3,RW4,and RW-6 using bailing <br /> RW4 14.26 15.57 1.31 100.91 recovery method.Reinstalled SoakEZ sacks in RW-2 and RW-6.Ending recovery tank <br /> RW-5 - 14.20 - volume approximately 6.2 gallons. <br /> RW-6 14.75 15.10 0.35 3.32 <br /> ' RW-I - 14.34 - <br /> RW-2 14.98 15.34 0.36 21.53 Initial product recovery tank volume approximately 6.2 gallons.Recovered <br /> 11/9/05 RW-3 14.99 15.05 0.06 22.34 approximately 1.0 gallon ofproduct from RW-2,RW-4,and RW-6 using bailing <br /> RW4 14.21 15.58 1.37 101.41 recovery method.Reinstalled SoakEZ socks in RW-2 and ME Ending recovery tank <br /> RW-5 - 14.16 - volume approximately 72 gallons. <br /> ' RW-6 14.84 15.07 0.23 3.57 <br /> -FW--1 14.38 <br /> RW-2 15.03 15.55 0.52 21.73 Initial product recovery tank volume approximately 7.2 gallons.Recovered <br /> 11i 18/05 RW-3 15.05 15.12 0.07 22.34 <br /> RW4 14.26 15.58 1.32 10251 approximately 1.4 gallon ofproduct from RW-2,RW4,and RW-6.Reinstalled SoakEZ <br /> ' RW-5 - 14.22 _ socks in RW-2 and RW-6.Ending recovery tank volume approximately 8.6 gallons. <br /> RW-6 14.74 15.16 0.42 3.67 <br /> RW-1 4.37 <br /> RW-2 14.96 15.68 0.72 22.13 Initial product recovery took volume approximately 8.6 gallons.Recovered <br /> 12/9/05 RW-3 15.05 15.11 0.06 22.34 <br /> RW-4 14.25 15.58 1.33 103.51 approximately 1.6 gallon ofpsrociuct from RW- <br /> 2,RW4,and RW-6.Reinstalled SookEZ <br /> RW-5 1411 socks in RW-2 and RW-6.Ending recovery tank volume approximately 10.2 gallons. <br /> RW-6 14.69 15.33 0.64 3.87 <br /> RW-1 - 14.24 - <br /> RW-2 14.88 15.74 0.86 22.49 <br /> RW-3 14.84 14.86 0.02 22,35 Initial product recovery tank volume approximately 10.2 gallons.Recovered <br /> 12/22/05 <br /> RW-5 14.09 15.34 1.25 104.04 approximately 1.0 gallon of product from RW-2,RW-3,RW-4,and RW-6.Ending <br /> RW-5 - 12.89- - recovery tank volume approximately 11.2 gallons. <br /> RW-6 14.55 14.75 0.20 3.96 <br /> XdPrajec1\7000_p07064 Jones Det Co(previously PNA)O064e Diesel RecovewRepads13p151Table axis Page 11 of 34 <br />