Laserfiche WebLink
f <br /> �i VERIFICATION LABORATO] 'NALYSIS <br /> TANK TANK TPH-G TPH-D BTX & E CL HC' TOTAL MTBE METALS PCB <br /> # CONTENTS 8015 8015 8020 8010 LEAD TBA,DIPE 'ICAP/ 8270 <br /> 8260 8260 8260 8240 7420' �E AES or 8080 q <br /> 7421 8020 AA <br /> 8260 <br /> LEADED GAS X X X X <br /> UNL GAS X X X <br /> DIESEL X X .- <br /> KEROSENE X .X <br /> - UNK FUEL X X X X X <br /> PROD. OIL X X <br /> CHLOR. <br /> SOLVENTS X X <br /> NONCHLOR <br /> SOLVENTS X X X <br /> WASTE\ <br /> USED OIL X X X X X X i <br /> All analysis methods are the designated EPA methods described in EPA.SW 846, Third Edition. 'Those methods not found in <br /> SW 846 are specifically noted below. Refer to the "SWRCB LUFT Field Manuai% Appendix D (B), Table 3-5 on page A20 I <br /> for minimum detection limits for motor vehicle.fuel (gasoline and.diesel). Refer to 1-2-3 "Regional Board Staff <br /> I <br /> Recommendations for Initial Evaluation and Investigation of UST's" for the waste and motor oil minimum detection limits. <br /> Detection Limits that remain below the MCL, STLC or Allowable Limit of the contaminant in question will be accepted, <br /> however laboratory shall utilize the most conservative method. <br /> k <br /> LABORATORY ANALYSES TERMINOLOGY: I <br /> TPH-G Total Petroleum Hydrocarbon, Gasoline, GC/FID (5030) 8015 mod or GC/MS 8260 . I <br /> TPH-D Total Petroleum Hydrocarbon, Diesel, GC/FID (3550).'8015 mod or GC/MS 8260 <br /> BTX & E Benzene, Toluene, Xylene & EthylBenzene, GC/PID 8020 or GC/MS 8260 j <br /> CL HC Chlorinated Hydrocarbon, GC/HSD 8010, GC/MS 8240 <br /> TOTAL LEAD Total lead, AA 7420, AA 7421 or ICP-AES 6010 <br /> MTBE Methyl Tertiary Butyl Ether, GCIPID 8020 and confirmed by GC/MS 8260 <br /> METALS ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption <br /> Spectrometry 7000. Metals: Cadmium, Chromium III and VI, Lead, Zinc and Nickel. i <br /> PCB Polychlorinated Biphenyls, GC/MS 8270 or 8080 <br /> GC-FID Gas Chromatography. FIame Ionization Detection <br /> Method 3050 Acid digestion f <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation, extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC . Quality Aisurance/Quality Control. .. <br /> Notes: To.avoid false positive detection of benzene, benzene-free solvents are to be used. Fused capillary columns are t <br /> preferred to packed columns; a packed column may be used as a "first cut" with "dirty" samples or once the hydrocarbons have <br /> been characterized and proper QA/QC is followed. j <br /> For drinking water sources, EPA recommends that the 500 series for volatile organic should be used in preference to the 600 t <br /> series because the detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal <br /> contamination may require further analysis. PHS-EHD recommends holding.those samples until disposal is indicated.- <br /> EH 23 046 (Revised 10/24/97) Page 8 <br />