Laserfiche WebLink
Cofi <br /> LAB CORE LABORATORIES <br /> 16 <br /> Q U A L I T Y C 0 N T R 0 L R E S U L T S <br /> .lob Number 981689 Date 11/11/98 <br /> CUSTOMER Fluor Daniel GTI PROJECT SL/STOCKTON 020632 ATTN. Shelby Lathrop <br /> QC Type Description Reag Code Lab ID Dilution Factor Date Time <br /> LCD Laboratory Control Sample Duplicate 08110204 11/02/98 100] <br /> Parameter/Test Description QC Result QC Result True Value Orig Value Calc Result * Limits <br /> asoline Range Petroleum Hydrocarbons 1085 1068 1000 0 108 5 % 50-150 <br /> 1 6 R 20 <br /> Aviation Gasoline 1085 1068 1000 0 108 5 % 50-150 <br /> 1 6 R 20 <br /> MS Matrix Spike 08110204 981662-2 11/03/98 0138 <br />■ Parameter/Test Description QC Result QC Result True Value Orig Value Calc Result * Limits <br /> gasoline Range Petroleum Hydrocarbons 1445 1000 0 288 116 % 50-150 <br /> Aviation Gasoline 1445 1000 0 288 116 % 50-150 <br /> MSD Matrix Spike Duplicate 08110204 981662-2 11/03/98 0205 <br /> Parameter/Test Description QC Result QC Result True Value Orig Value Calc Result * Limits <br /> or ine Range Petroleum Hydrocarbons 1451 1445 1000 0 288 116 % 50-150 <br /> 0 4 R 20 <br /> Aviation Gasoline 1451 1445 1000 0 288 116 % 50-150 <br /> 0 4 R 20 <br /> CCV Continuing Calibration Verification 08110203 11/03/98 0354 <br /> Parameter/Test Description QC Result QC Result True Value Orig Value Calc Result * Limits <br /> asoline Range Petroleum Hydrocarbons 1066 1000 0 107 % 80-120 <br /> Aviation Gasoline 1066 1000 0 107 % 80-120 <br /> CCV Continuing Calibration verification 08110203 11/03/98 0947 <br /> Parameter/Test Description QC Result QC Result True Value Orig Value Calc Result * Limits <br /> asoline Range Petroleum Hydrocarbons 1093 1000 0 109 % 80-120 <br /> viation Gasoline 1093 1000 0 109 % 80-120 <br /> MB Method Blank 11/03/98 113b <br /> Parameter/Test Description QC Result QC Result True Value Orig Value Calc Result * Limits <br /> I asoLine <br /> Range Petroleum Hydrocarbons 0 T 100 <br /> viation Gasoline 0 100 <br /> LrS �lLaborato`ry Control Sample 08110204 11/03/98 1202 <br /> Parameter/Test Description QC Result QC Result True Value Orig Value Calc Result * Limits <br /> ine Range Petroleum Hydrocarbons 1166 1000 0 116 6 % 50-150 <br /> Page 12 <br /> * %-% REC R-RPD A-ABS Diff D-% Diff <br /> me.,nylwai a ait opnam a merwnlar.p a rAnlaned n Ina aeon a e o .ed upo tr m ron a ti� lea PP ri ny m ci e r Io wn�e e e� e ann�,I aent e I s,v n min m.rn ne r w o ins oP �s o n e P rl�I e� <br /> eKCe"xtl IWtI-enI IM ne51.bPment OI Co B�Oo elor el CPre La OP talc Mwe n F now c O 'P x emt I T e 0 9 0 mP ped Pf®nV tY Pe u]e P n N 0 cPy m c me Y WpM WeOo IY—Pw oOvr sl M 0 0 PI t Mono 5 I <br /> y n qt Pai o Pt he m ai P ePdtY ^'� wnn n rgnneel o w Ih tvn ch such a +d o t O upon 1,am es Pn.Vileisoe tf Tn t Pan h.. w1 be eP Pew a whc0 0 t the w Ile �pP o a o1 Co Luno oto <br />