Laserfiche WebLink
GREGG IN SITU, INC. ATC - <br />' October 16, 2002 Diamond Walnut Growers <br /> 02-143ma Stockton, Ca <br />' In situ groundwater samples were taken at two locations Groundwater samples were <br /> collected using a Hydropunch® type groundwater sampling system (figure 2) The <br />' groundwater sampler operates by pushing 1 75 inch diameter hollow rods with a <br /> retrievable tip A stainless steel filter screen is attached to the tip At the desired <br /> sampling depth, the rods are retracted exposing the filter screen and allowing for <br /> groundwater infiltration A small diameter bailer is then used to collect groundwater <br /> samples through the hollow rod <br />' 3.0 CONE PENETRATION TEST DATA & INTERPRETATION <br /> The cone penetration test data is presented in graphical form Penetration depths are <br />' referenced to existing ground surface This data includes CPT logs of measured soil <br /> parameters and a computer tabulation of interpreted soil types along with additional <br /> geotechnical parameters and pore pressure dissipation data <br />' The stratigraphic interpretation is based on relationships between corse bearing (qc), <br /> sleeve fnction (fs), and penetration pore pressure (U) The friction ratio (Rf), which is <br /> sleeve friction divided by cone bearing, is a calculated parameter which is used to infer <br /> soil behavior type Generally, cohesive soils (clays) have high friction ratios, low cone <br /> bearing and generate large excess pore water pressures Cohesionless soils (sands) <br /> 1 have lower friction ratios, high cone beanng and generate little in the way of excess <br /> pore water pressures <br /> Pore Pressure Dissipation Tests (PPDT's) were taken at various intervals in order to <br /> measure hydrostatic water pressures and approximate depth to groundwater table In <br /> addition, the PPDT data can be used to estimate the horizontal permeability (kh) of the <br />' soil The correlation to permeability is based on the time required for 50 percent of the <br /> measured dynamic pore pressure to dissipate 050) The PPDT correlation figure (figure <br /> 3) is provided in the Appendix <br /> 1 The interpretation of soils encountered on this project was carried out using recent i <br /> correlations developed by Robertson et al, 1988 It should be noted that it is not always <br />' possible to clearly identify a soil type based on qc, fs and U In these situations, <br /> experience and judgement and an assessment of the pore pressure dissipation data <br /> should be used to infer the soil behavior type The soil classification chart (figure 4) <br />' used to interpret soil types based on qc and Rf is provided in the Appendix <br /> Interpreted output requires that depth of water be entered for calculation purposes, <br /> where depth to water is unknown an arbitrary depth in excess of 10 feet of the deepest <br /> sounding is entered as the groundwater depth <br />