Laserfiche WebLink
CASTLE ANALYTICAL LABORATORY <br /> Environmental Testing Services P.O. Box 1360, Winton, CA. 95388 Phone: f209) 384-2930 <br /> ' Certificate #2079 Fax: (209) 384-1507 <br /> Advanced GeoEnvironmental, Inc. Client Project ID:95-0197 Sampled: 1-24-96 <br /> ' of Northern California Reference Number: 658 Received: 1-25-96 <br /> 1803 West March Lane, Suite A Sample Description:Water Extracted: 1-25-96 <br /> Stockton, CA 95207 Sample Prep/Analysis Method: 8015M, 8020 Analyzed: 1-25-96 <br /> Attn:Tim Cuellar Lab Numbers. 658-9W Reported: 2-1-96 <br /> 1 <br /> ' TOTAL PETROLEUM HYDROCARBONS - GASOLINE RANGE <br /> WITH BTEX DISTINCTION <br /> ' ANALYTE REPORTING LIMIT SAMPLE ID <br /> 631420 <br /> (ug/L) lug/L) <br /> BENZENE 0.50 160 <br /> TOLUENE 0.50 140 <br /> ETHYL BENZENE 0.50 95 <br /> TOTAL XYLENES 1.0 570 <br /> MGASOLINE RANGE <br /> HYDROCARBONS 50 5800 <br /> ' Report Limit Multiplication Factor: 10 <br /> 1 <br /> Surrogate % Recovery: FOAM,%IPIO-94.4% <br /> Instrument ID: VAR-GC1 <br /> ' Practical Quantitation Limit = Reporting Limit x Report Limit Multiplication Factor <br /> Analytes reported as ND were not detected or below the Practical Quantitation Limit <br /> ANALYST: tz e { APPROVED BY: �u�{ <br /> Carl J. Cone Jes C. Phillips <br /> Environmental Lab Director <br />