6 <br /> 5.4 Soil Disposal <br /> Soil generated as part of soil boring activities was temporarily stored on Site under plastic sheeting. <br /> ' The soil was transported to, and recycled at, American Remedial Technologies in Lynwood, <br /> California on June 4, 2004. A copy of the soil disposal manifest has been attached in Appendix E. <br /> ' 6.0 CONCLUSIONS <br /> Based on data collected during this investigation and past investigations,the following conclusions <br /> have been made: <br /> • The mass of soil which contains concentrations of TPH-d appears to be minimal and confined <br /> to the area of soil sample D8-2.Soil samples collected from soil boring B 1,drilled and sampled <br /> in the approximate location of soil sample D8-2,did not contain concentrations of TPH-d,TPH- <br /> ' g, BTEX or fuel oxygenates. <br /> • Volatile petroleum hydrocarbon analytes such as benzene and fuel oxygenates were not detected <br /> ' in any of the soil samples analyzed as part of this investigation or in soil samples collected as <br /> part of fuel system upgrade activities. <br /> ' 7.0 RECOMMENDATION <br /> Based on the over-excavation of soil containing residual concentrations ofpetroleum hydrocarbons, <br /> ' from the immediate area beneath the east-central fuel dispenser, and additional site assessment <br /> activities in this area, FREY recommends that a no further action letter be issued for the Site. <br /> 8.0 LIMITATIONS <br /> The judgements described in this report are professional opinions based solely within the limits of <br /> the scope of work authorized,and pertain to conditions judged to be present or applicable at the time <br /> the work was performed. Future conditions may differ from those described herein,and this report <br /> ' is not intended for future evaluations of this Site unless an update is conducted by a consultant <br /> familiar with environmental assessments. <br /> ' This report was compiled partially from information supplied to FREY Environmental, Inc. from <br /> outside sources, other information that is in the public domain and a visual inspection of the <br /> property. FREY Environmental, Inc. makes no warranty as to the accuracy of statements made by <br /> ' others,which may be contained in this report,nor are any other warranties or guarantees,expressed <br /> or implied, included or intended by the report, except that it has been prepared in accordance with <br /> the current accepted practices and standards consistent with the level of care and skill exercised <br /> ' under similar circumstances by other professional consultants or firms performing similar services. <br /> tFREY <br />