PO EO%1B'B STI SP-001 <br /> POWERS •°"" "° °'° <br /> Fe 707166 MIO VALLEY AGRICULTURE SERVICES MIO VALLEY AO <br /> FP%]°]8429< <br /> ENGINEERING&INSPECTION,INC. wxwyowenKeam Diesel Fuel Tank <br /> Tank Suitability for Service Statement <br /> This facility is regulated by all federal, state, and local regulations. The Code of Federal Regulations, 40 <br /> CFR 112, requires that the facility maintain a Spill Prevention, Control, and Countermeasures(SPCC)plan <br /> that adheres to the industry standard requirements for regular inspections. The Steel Tank Institute (STI) <br /> SP001 Standard requires that the aboveground storage tanks (ASTs) be formally inspected based on the <br /> category of the AST. <br /> Next Inspection Schedules <br /> STI SP001 recommends the interval to the next inspection be determined based on known tank category <br /> and volume. This 10,000 gallon tank is currently equipped with a spill control system in the form of a berm <br /> secondary containment.The tank has an inherent continuous release detection method (CRDM)in the form <br /> of an elevated tank on saddle supports. The tank stores diesel fuel at ambient temperature. Based on the <br /> current configuration,the tank is classified as Category 1. Per inspection interval definitions outlined in STI <br /> SP001, PEI recommends the following inspection schedule: <br /> • An out-of-service, internal inspection inspection is not required. <br /> • A leak test in accordancewith STI SP001 is not required. <br /> • An external, in-service inspection should be scheduled no more than 20 years from the current <br /> inspection date or sooner if a change in tank condition occurs. However, more stringent governing <br /> regulatory intervals of inspection may supersede this interval. <br /> Required Repairs for Continued Service <br /> 1. No required repairs for continued service is required for Tank Diesel Fuel. <br /> Considerations or Recommended Repairs <br /> 2. There is a minor product stain on the 2 Yin top size nozzle. Clean the area around the nozzle and <br /> monitor the condition of the nozzle. Repair as necessary. <br /> 3. Consider installing grounding cables per NFPA 30 Section 6.5.4. <br /> 4. Rust and coating failure was identified on all threaded and flanged connections,consider applying touch <br /> up coatings to these areas.Monitorthe condition ofthe coatings and applytouch up coatings as needed <br /> to prevent corrosion damage to the shell, ends, piping, and appurtenances. <br /> 5. Minor crackswere identified in the concrete containment which could hinder the containments ability to <br /> contain product. Consider sealing the concrete cracking in the concrete dike <br /> Non-Mandatory Items <br /> 6. This tank is equipped with threaded components and piping, which are known to develop seeps. <br /> Monitor these areas during monthly and annual inspections. <br /> STAWIMDV YAGRS:LL MSEMJ STM DESELMELMDV YA MW Page UNePnMGBlY1S <br /> OAIBPHI. <br />