Laserfiche WebLink
PO EO%1B" STI SP-001 <br /> POWERS e°"" "° '° <br /> Fe 70796]IN MID VALLEY AGRICULTURE SERVICES MIO VALLEY AO <br /> FP%]°]B4]IDG <br /> ENGINEERING&INSPECTION,INC. mnW{wWM9lLLUm Diesel Fuel Tank <br /> 2.2 Monthly Inspection Checklist <br /> General Inspection Information <br /> 1. Inspection Date: 8/13/2019 <br /> 2. Retain Until Date(36 monthsfrom inspection date): 8/13/2022 <br /> 3. Prior Inspection Date: Unknown <br /> 4. Inspector(s)Name(s): Dylan Macy <br /> 5. Tanks Inspected (ID#'s): Diesel Fuel <br /> 1.0 Tank Containment Status Comment <br /> Water in primary tank,secondary containment, <br /> 1.1 interstice, ors ill container? NO <br /> 1.2 Debris or fire hazard in containment? Yes Minor dirt and debris under tanks <br /> 1.3 Drain valves operable and in a closed position? Yes <br /> 1.4 <br /> Containment egress pathways clear and gates/doors <br /> operable? <br /> Yes <br /> 2.0 Leak Detection Status Comment <br /> 2.1 Visible signs of leakage around the tank,concrete pad, YeMinor product stain on 2/%-in top <br /> Yes containment, ring-wall or ground? size nozzle <br /> Is the leak detector in good condition(Check tube cap <br /> for corrasion and proper operation)? If a Kruger <br /> manual leak indicator is installed, remove the red ring <br /> 2.2 and clear cap and check to see that the red indicator yes <br /> moves up and down about 1 inch freely. Also,check <br /> forweathering or cracks in the clear cap. If electronic <br /> leak detection is installed,check it by using the test <br /> button)? <br /> 3.0 Tank Attachment and Appurtenances Status Comment <br /> 3.1 Ladder and platform structure secure with no sign of yes Minor corrosion resent <br /> severe corrosion or damage? <br /> p <br /> 3.2 <br /> Tank Liquid Level Gauge readable and in good <br /> condition? Yes <br /> 3.3 Are all tank openings properly sealed? Yes <br /> 3.4 <br /> Are all nozzles, hoses and fittings in good condition Inc <br /> wear and tear? Yes <br /> 3.5 <br /> Are trigger mechanism on nozzle in good condition(no <br /> metal fati ue or mechanical failure)? <br /> Yes <br /> 4.0 Other Conditions Status Comment <br /> Are there other conditions that should be addressed fo <br /> 4.1 continued safe operation or that may affect the site No <br /> SPCC Ian? <br /> Is the pump motor in good condition (no signs of over- <br /> 4.2 heatingor excessive wear? Yes <br /> 4.3 <br /> Tank in good clean condition (cleanliness,good paint <br /> condition no rustingpresent)?Are there are an si ns Yes <br /> m WWIMDVPLLEYRCFIDLL MSEMd STM DESELMELMDV YR MW Page ° PnMd WY1S <br /> OAIBPs.. <br />