Laserfiche WebLink
PO EO%1B" STI SP-001 <br /> POWERS GE~"" B <br /> ' `AE,G <br /> Fe 70796]IN MID VALLEY AGRICULTURE SERVICES MID VALLEY AO <br /> FP%]G]B4]IDG <br /> ENGINEERING&INSPECTION,INC. mnW{wWM9lLLUm Unleaded Gasoline <br /> Fuel Tank <br /> 2.2 Monthly Inspection Checklist <br /> General Inspection Information <br /> 1. Inspection Date: 8/13/2019 <br /> 2. Retain Until Date(36 monthsfrom inspection date): 8/13/2022 <br /> 3. Prior Inspection Date: Unknown <br /> 4. Inspectors)Name(s): Dylan Macy <br /> 5. Tanks Inspected(ID#'s): Unleaded Gasoline Fuel <br /> 1.0 Tank Containment Status Comment <br /> Water in primary tank, secondary containment, <br /> 1.1 interstice, ors ill container? NO <br /> 1.2 Debris or fire hazard in containment? Yes Minor dirt and debris under tanks <br /> 1.3 Drain valves operable and in a closed position? Yes <br /> 1.4 <br /> Containment egress pathways clear and gates/doors <br /> operable? <br /> Yes <br /> 2.0 Leak Detection Status Comment <br /> 2.1 <br /> Visible signs of leakage around the tank,Concrete pad, <br /> containment, ring-wall or round? Yes <br /> Is the leak detector in good Condition (Check tube Cap <br /> for corrosion and proper operation)? If a Kruger <br /> manual leak indicator is installed, remove the red ring <br /> 2.2 and clear cap and check to see that the red indicator yes <br /> moves up and dawn about 1 inch freely. Also,check <br /> forweathering or cracks in the clear cap. If electronic <br /> leak detection is installed,check it by using the test <br /> button)? <br /> 3.0 Tank Attachment and Appurtenances Status Commend <br /> 3.1 Ladder and platform structure secure with no sign of yes Minor Corrosion present <br /> severe Corrosion or dama e? <br /> 3.2 <br /> Tank Liquid Level Gauge readable and in good <br /> condition? Yes <br /> 3.3 Are all tank openings properly sealed? Yes <br /> 3.4 <br /> Are all nozzles, hoses and fittings in good condition(n <br /> wear and tear? Yes <br /> 3.5 <br /> Are trigger mechanism on nozzle in good condition(no <br /> metal fatigue or mechanical failure)? <br /> Yes <br /> 4.0 Other Conditions Status Commend <br /> Are there other Conditions that should be addressed fo <br /> 4.1 continued safe operation or that may affect the site No <br /> SPCC Ian? <br /> Is the pump motor in good condition (no signs of over- <br /> 4.2 heatingor excessive wear? Yes <br /> 4.3 <br /> Tank in good clean Condition(cleanliness,good paint <br /> condition, no rustingpresent)?Are there are an ai mi yes <br /> STAWi MG VMLEYRCRGLLNI�SE2NCESimO LNIEPEEG G0.4GlHEMG VIIIEY Page INteP^ eY'P <br /> RG IffVO <br /> OAIBPEBI Rc <br />